240 V Electric Tankless kW and Circuit Amps
Estimate electric tankless heater current at 240 V, compare an equal circuit split and review the manufacturer circuit schedule.
Inputs
Results ↓Results
Example estimate- Winter inlet temperature
- 65 °F
- Required temperature rise
- 55 °F
- Useful heat into water
- 66,000 BTU/h
- Gas input at steady efficiency
- 70,213 BTU/h
- Electric input
- 19.54 kW
- Total operating current
- 81.4 A
- Operating current per circuit
- 40.7 A
- Breaker comparison per circuit
- 45 A
- Use the manufacturer’s flow-at-rise chart and listed circuit schedule. Breaker figures here are only comparisons.
Calculation inputs
- Showers in use
- 1
- Showers hot-side flow each
- 2.4 GPM
- Dishwasher in use
- 0
- Dishwasher hot-side flow each
- 1 GPM
- Clothes washer in use
- 0
- Clothes washer hot-side flow each
- 1.5 GPM
- Faucets in use
- 0
- Faucets hot-side flow each
- 0.6 GPM
- Winter groundwater example
- Warm US example
- Target heater outlet temperature
- 120 °F
- Gas efficiency basis
- Steady-state thermal efficiency
- Gas efficiency value
- 94 %
- Electric heating efficiency
- 99 %
- Electric supply voltage
- 240 V
- Equal electric circuits for comparison
- 2
Worked example
The example draws 2.4 GPM with a 55°F rise. The calculator reports input kW, total current and an illustrative per-circuit value if two even circuits share the load.
Peak hot-side demand 2.4 GPM
What to check next
Check service and panel capacity with a qualified installer. Use the selected model’s nameplate and listed wiring instructions for voltage, breakers, conductor ratings and circuit count.
Formulas and assumptions
- Fixture flow
- Peak hot-side GPM = Σ(simultaneous fixture count × hot-side GPM each). Temperature rise = heater outlet minus winter inlet.
- Heater input
- Heat delivered to water ≈ 500 × GPM × rise in °F. Divide by steady gas efficiency for burner input, or by 3,412.14 and electric efficiency for electric kW.
- Circuit comparison
- Amps = kW × 1,000 ÷ volts for the single-phase example. Split equally among the assumed circuits and compare with the next standard breaker size. Use the manufacturer’s circuit schedule for installation.
Frequently asked questions
Can I choose one breaker just by dividing tankless watts by 240?
That division estimates total operating current. Actual equipment can require several independent circuits at listed ratings and may have service-size requirements.
What should I check before using a 240 V heater on a 208 V supply?
Read the equipment rating for 208 V, including its reduced output and required circuit configuration. The modeled current assumes the entered power is delivered.