Point-of-Use Tankless Heater for a Kitchen Sink
Size a single kitchen faucet tankless heater using the hot-side draw, 60°F measured inlet and a lower outlet temperature.
Inputs
Results ↓Results
Example estimate- Winter inlet temperature
- 60 °F
- Required temperature rise
- 50 °F
- Useful heat into water
- 22,500 BTU/h
- Gas input at steady efficiency
- 23,936 BTU/h
- Electric input
- 6.66 kW
- Total operating current
- 55.5 A
- Operating current per circuit
- 55.5 A
- Breaker comparison per circuit
- 60 A
- Use the manufacturer’s flow-at-rise chart and listed circuit schedule. Breaker figures here are only comparisons.
Calculation inputs
- Showers in use
- 0
- Showers hot-side flow each
- 2 GPM
- Dishwasher in use
- 0
- Dishwasher hot-side flow each
- 1 GPM
- Clothes washer in use
- 0
- Clothes washer hot-side flow each
- 1.5 GPM
- Faucets in use
- 1
- Faucets hot-side flow each
- 0.9 GPM
- Winter groundwater example
- Measured winter inlet
- Measured inlet temperature
- 60 °F
- Target heater outlet temperature
- 110 °F
- Gas efficiency basis
- Steady-state thermal efficiency
- Gas efficiency value
- 94 %
- Electric heating efficiency
- 99 %
- Electric supply voltage
- 120 V
- Equal electric circuits for comparison
- 1
Worked example
A single faucet needs 0.9 hot-side GPM with 50°F of lift. Check power at an assumed 120 V supply, and compare it with equipment that can actually deliver that temperature rise.
Peak hot-side demand 0.9 GPM
What to check next
Verify minimum activation flow, allowable outlet range and available electrical service. Also check fixture scald protection and temperature requirements for your use.
Formulas and assumptions
- Fixture flow
- Peak hot-side GPM = Σ(simultaneous fixture count × hot-side GPM each). Temperature rise = heater outlet minus winter inlet.
- Heater input
- Heat delivered to water ≈ 500 × GPM × rise in °F. Divide by steady gas efficiency for burner input, or by 3,412.14 and electric efficiency for electric kW.
- Circuit comparison
- Amps = kW × 1,000 ÷ volts for the single-phase example. Split equally among the assumed circuits and compare with the next standard breaker size. Use the manufacturer’s circuit schedule for installation.
Frequently asked questions
Why might a small tankless kitchen sink heater shut off at a trickle?
Flow-activated heaters have a minimum threshold. A low-flow faucet or mixing valve may leave the hot-side stream below that threshold.
How can I check a kitchen point-of-use unit’s published GPM?
Find the model’s chart at the actual temperature rise. A maximum GPM claim at warm inlet water can overstate performance at your measured inlet.