Point-of-Use Tankless Heater for a Kitchen Sink

Size a single kitchen faucet tankless heater using the hot-side draw, 60°F measured inlet and a lower outlet temperature.

Simultaneous hot-water draw
Water temperature and heater

Results

Example estimate
Peak hot-side demand0.9 GPM
Showers 0 GPM Dishwasher 0 GPM Clothes washer 0 GPM Faucets 0.9 GPM
The bars include fixtures drawing hot water at the same time.
Winter inlet temperature
60 °F
Required temperature rise
50 °F
Useful heat into water
22,500 BTU/h
Gas input at steady efficiency
23,936 BTU/h
Electric input
6.66 kW
Total operating current
55.5 A
Operating current per circuit
55.5 A
Breaker comparison per circuit
60 A
  • Use the manufacturer’s flow-at-rise chart and listed circuit schedule. Breaker figures here are only comparisons.

Worked example

A single faucet needs 0.9 hot-side GPM with 50°F of lift. Check power at an assumed 120 V supply, and compare it with equipment that can actually deliver that temperature rise.

Peak hot-side demand 0.9 GPM

What to check next

Verify minimum activation flow, allowable outlet range and available electrical service. Also check fixture scald protection and temperature requirements for your use.

Formulas and assumptions

Fixture flow
Peak hot-side GPM = Σ(simultaneous fixture count × hot-side GPM each). Temperature rise = heater outlet minus winter inlet.
Heater input
Heat delivered to water ≈ 500 × GPM × rise in °F. Divide by steady gas efficiency for burner input, or by 3,412.14 and electric efficiency for electric kW.
Circuit comparison
Amps = kW × 1,000 ÷ volts for the single-phase example. Split equally among the assumed circuits and compare with the next standard breaker size. Use the manufacturer’s circuit schedule for installation.

Frequently asked questions

Why might a small tankless kitchen sink heater shut off at a trickle?

Flow-activated heaters have a minimum threshold. A low-flow faucet or mixing valve may leave the hot-side stream below that threshold.

How can I check a kitchen point-of-use unit’s published GPM?

Find the model’s chart at the actual temperature rise. A maximum GPM claim at warm inlet water can overstate performance at your measured inlet.

More sizing examples

Open the general tankless water heaters calculator