Kitchen Exhaust CFM and Room Air Changes

Use a 1,620 ft³ kitchen to compare a room air-change target with an intermittent ducted range-hood baseline.

Room and air changes

Floor area × average ceiling height, in the unit selected above.

Scenario values are editable planning examples.

Measured air and filtration

Use delivered outdoor supply or exhaust. Count balanced airflow once.

Results

Example estimate
Outdoor-only fan or ERV target270 CFM
ACH airflow target 270 CFM Scenario outdoor baseline 100 CFM Existing outdoor airflow 0 CFM Added HEPA CADR 170 CFM
Added filtration assumes the outdoor baseline is met first.
Room volume
1,620 ft³
Room volume in metric
45.87 m³
Flow for target ACH
270 CFM
Scenario outdoor baseline
100 CFM
Added outdoor airflow for full ACH
270 CFM
Outdoor baseline still needed
100 CFM
Added particle CADR after baseline
170 CFM CADR
Existing outdoor ACH
0 ACH
Existing particle clean-air ACH
0 eACH
  • The 100 CFM vented-hood example is a baseline for comparison. Verify cooking-source capture, local code and makeup air.

Worked example

A 1,620 ft³ kitchen at 10 ACH needs 270 CFM by volume. The hood comparison also displays an example outdoor exhaust baseline. A good capture area can control cooking emissions without treating the whole room the same way.

Outdoor-only fan or ERV target 270 CFM

What to check next

Check hood width, mounting height and capture performance for the cooktop. Verify whether makeup air or interlocks are required for the chosen flow.

Formulas and assumptions

Air exchange
CFM = volume in ft³ × ACH ÷ 60. Convert cubic meters to cubic feet by multiplying by 35.3147.
Whole-dwelling baseline
62.2 example airflow = 0.03 × dwelling ft² + 7.5 × (bedrooms + 1), before adjustments. Use at least one bedroom in the equation. Bathroom and kitchen presets show example intermittent source exhaust flows.
Outdoor flow and filtered air
Outdoor-only sizing uses the larger of ACH flow and the scenario outdoor baseline. For particle filtration, first meet the outdoor baseline, then subtract outdoor CFM and existing CADR from target clean-air CFM.

Frequently asked questions

Will a recirculating kitchen hood replace a ducted exhaust flow?

A recirculating hood can treat some particles or odors. It does not deliver outdoor exhaust or remove all cooking moisture and gases.

Why compare kitchen room volume when sizing a range hood?

Room air changes show general dilution. Hood capture, duct pressure and cooking appliances also determine source control.

More sizing examples

Open the general ventilation airflow calculator