Kitchen Exhaust CFM and Room Air Changes
Use a 1,620 ft³ kitchen to compare a room air-change target with an intermittent ducted range-hood baseline.
Inputs
Results ↓Results
Example estimate- Room volume
- 1,620 ft³
- Room volume in metric
- 45.87 m³
- Flow for target ACH
- 270 CFM
- Scenario outdoor baseline
- 100 CFM
- Added outdoor airflow for full ACH
- 270 CFM
- Outdoor baseline still needed
- 100 CFM
- Added particle CADR after baseline
- 170 CFM CADR
- Existing outdoor ACH
- 0 ACH
- Existing particle clean-air ACH
- 0 eACH
- The 100 CFM vented-hood example is a baseline for comparison. Verify cooking-source capture, local code and makeup air.
Calculation inputs
- Ventilation scenario
- Kitchen exhaust
- Volume unit
- Cubic feet (ft³)
- Room or dwelling volume
- 1620 ft³
- Target air changes per hour
- 10 ACH
- Existing outdoor air
- 0 CFM
- Existing particle clean-air delivery
- 0 CFM CADR
Worked example
A 1,620 ft³ kitchen at 10 ACH needs 270 CFM by volume. The hood comparison also displays an example outdoor exhaust baseline. A good capture area can control cooking emissions without treating the whole room the same way.
Outdoor-only fan or ERV target 270 CFM
What to check next
Check hood width, mounting height and capture performance for the cooktop. Verify whether makeup air or interlocks are required for the chosen flow.
Formulas and assumptions
- Air exchange
- CFM = volume in ft³ × ACH ÷ 60. Convert cubic meters to cubic feet by multiplying by 35.3147.
- Whole-dwelling baseline
- 62.2 example airflow = 0.03 × dwelling ft² + 7.5 × (bedrooms + 1), before adjustments. Use at least one bedroom in the equation. Bathroom and kitchen presets show example intermittent source exhaust flows.
- Outdoor flow and filtered air
- Outdoor-only sizing uses the larger of ACH flow and the scenario outdoor baseline. For particle filtration, first meet the outdoor baseline, then subtract outdoor CFM and existing CADR from target clean-air CFM.
Frequently asked questions
Will a recirculating kitchen hood replace a ducted exhaust flow?
A recirculating hood can treat some particles or odors. It does not deliver outdoor exhaust or remove all cooking moisture and gases.
Why compare kitchen room volume when sizing a range hood?
Room air changes show general dilution. Hood capture, duct pressure and cooking appliances also determine source control.