Mini-Split Size for a West-Facing Sunroom

Compare sunroom cooling with and without shade using glazing area, effective R-values and the mini-split room-use adjustment.

Room and use
Envelope and glazing

50% is two sides of a square room.

Use 0 if a conditioned space is above.

Use 0 to omit floor loss. Slab edges need separate modeling.

Use the whole-window rating in Btu/(h·ft²·°F).

Use natural air changes, not ACH50 from a blower-door test.

Weather and equipment

Sets example weather. Use local design temperatures when available.

Results

Example estimate
Suggested nominal class24,000 BTU/h
Cooling23,793 BTU/h 433.8 BTU/h0 BTU/h19,978.8 BTU/h780.3 BTU/h2,600 BTU/hHeating7,378 BTU/h 863.8 BTU/h0 BTU/h5,445 BTU/h1,069.2 BTU/h0 BTU/h
Each bar uses the same BTU/h scale.
  • Walls and ceiling · 434 cool / 864 heat
  • Exposed floor · 0 cool / 0 heat
  • Windows and sun · 19,979 cool / 5,445 heat
  • Outdoor air leakage · 780 cool / 1,069 heat
  • People and equipment · 2,600 cool / 0 heat
Modeled cooling load
23,792.8 BTU/h
Modeled heating loss
7,378 BTU/h
Cooling load in tons
1.98 tons
Minimum nominal capacity
23,792.8 BTU/h
Cold-weather capacity
96.5 % of nominal
Heating output at design
23,160 BTU/h
Summer / winter design
92°F / 26°F
Modeled outdoor leakage
22.5 CFM

Worked example

The 300 ft² room has 275 ft² of west-facing glass. The late-afternoon gain makes it a poor match for a simple floor-area sizing rule. Test exterior shading by switching exposure, then compare the new cooling estimate.

Suggested nominal class 24,000 BTU/h

What to check next

Check the window SHGC, skylights and direct solar hours. Have the actual glazing and orientation modeled if the room remains uncomfortable even with the estimated cooling capacity.

Formulas and assumptions

Envelope load
BTU/h = Σ(area × ΔT ÷ effective R) + window area × U × ΔT. Exposed ceilings add a 10°F summer solar allowance.
Air and internal gains
Leakage CFM = room volume × ACH ÷ 60. Sensible airflow load uses 1.08 × CFM × ΔT. Cooling also includes 0.68 × CFM × the zone moisture difference in grains, window solar gain, people and equipment.
Capacity and tons
Cooling tons = cooling BTU/h ÷ 12,000. For heating, divide design heat loss by the capacity ratio. Size up to the first listed nominal class that meets the selected load.

Frequently asked questions

Do shades help sunroom sizing more than adding another adult to the load?

In this scenario, solar gain through the extensive glass is much larger than one person’s heat and moisture. Compare both changes directly in the inputs.

Should a sunroom mini-split be sized using the house’s average BTU per square foot?

Model the sunroom as its own zone. Its glass-to-floor ratio and exposure can differ sharply from the rest of the house.