½-Inch vs. ⅝-Inch PEX for Radiant Floors

Compare water velocity for ½-inch and ⅝-inch radiant tubing using the same circuit length and hydronic load.

Heated surface and tubing

Subtract walls, fixed cabinets and other areas without active tube.

Adds footage for turns and layout variation.

Manifold and heat load

Enter the one-way distance. The model adds supply and return tails.

Includes both tails. Use a lower limit when the hydraulic design calls for it.

Results

Example estimate
Total tubing including tails1,244 ft
SupplyReturn 212.8 ft active per loop
One circuit shown. Supply and return tails are included in the balanced loop length.
Balanced loop length
248.8 ft
Balanced circuits
5 loops
Manifold supply/return pairs
5 ports
Active tubing before tails
1,064 ft
Supply and return tails per loop
36 ft
Design floor load
22,800 BTU/h
Total manifold flow
4.56 GPM
Flow per loop
0.91 GPM
Modeled tubing velocity
1.13 ft/s
Tubing and assumed ID
PEX-B · 0.574 in ID
  • Verify tubing ID, bend radius, oxygen barrier, floor output and pump head for the installed system.

Worked example

The example starts with ⅝-inch PEX-B and a 10°F water drop. Change to ½-inch to see how the modeled inside diameter changes velocity at the same circuit flow.

Total tubing including tails 1,244 ft

What to check next

Check pump head using product-specific ID and circuit fittings. Choose hydronic tubing approved for the floor assembly and use an oxygen barrier when the system requires it.

Formulas and assumptions

Active tube
Active footage = floor area × 12 ÷ spacing in inches × (1 + routing allowance).
Balanced circuits
Circuit count = round up(active footage ÷ (loop limit − two manifold tails)). Balanced length = active footage ÷ circuits + tails.
Water flow
GPM = BTU/h ÷ (500 × supply-return ΔT). Divide system flow by the number of equally loaded circuits. The velocity uses representative tubing ID.

Frequently asked questions

Does ⅝-inch PEX reduce the tubing footage needed for a given floor?

Spacing and routing determine footage. A larger inside diameter changes water velocity and pressure drop, and design may allow different circuit choices.

Can I tell bend radius from whether the tubing is PEX-A or PEX-B?

Use the product’s bend-radius specification. The crosslinking method alone does not determine the exact installation geometry.

More sizing examples

Open the general radiant floor loops calculator