½-Inch vs. ⅝-Inch PEX for Radiant Floors
Compare water velocity for ½-inch and ⅝-inch radiant tubing using the same circuit length and hydronic load.
Inputs
Results ↓Results
Example estimate- Balanced loop length
- 248.8 ft
- Balanced circuits
- 5 loops
- Manifold supply/return pairs
- 5 ports
- Active tubing before tails
- 1,064 ft
- Supply and return tails per loop
- 36 ft
- Design floor load
- 22,800 BTU/h
- Total manifold flow
- 4.56 GPM
- Flow per loop
- 0.91 GPM
- Modeled tubing velocity
- 1.13 ft/s
- Tubing and assumed ID
- PEX-B · 0.574 in ID
- Verify tubing ID, bend radius, oxygen barrier, floor output and pump head for the installed system.
Calculation inputs
- Net heated floor area
- 760 ft²
- Tube spacing on center
- 9 in
- Nominal tubing size
- ⅝ in
- PEX type
- PEX-B
- Routing allowance
- 5 %
- Manifold distance per circuit
- 18 ft
- Maximum total circuit length
- 300 ft
- Design floor heat load
- 30 BTU/h·ft²
- Supply-to-return temperature drop
- 10 °F
Worked example
The example starts with ⅝-inch PEX-B and a 10°F water drop. Change to ½-inch to see how the modeled inside diameter changes velocity at the same circuit flow.
Total tubing including tails 1,244 ft
What to check next
Check pump head using product-specific ID and circuit fittings. Choose hydronic tubing approved for the floor assembly and use an oxygen barrier when the system requires it.
Formulas and assumptions
- Active tube
- Active footage = floor area × 12 ÷ spacing in inches × (1 + routing allowance).
- Balanced circuits
- Circuit count = round up(active footage ÷ (loop limit − two manifold tails)). Balanced length = active footage ÷ circuits + tails.
- Water flow
- GPM = BTU/h ÷ (500 × supply-return ΔT). Divide system flow by the number of equally loaded circuits. The velocity uses representative tubing ID.
Frequently asked questions
Does ⅝-inch PEX reduce the tubing footage needed for a given floor?
Spacing and routing determine footage. A larger inside diameter changes water velocity and pressure drop, and design may allow different circuit choices.
Can I tell bend radius from whether the tubing is PEX-A or PEX-B?
Use the product’s bend-radius specification. The crosslinking method alone does not determine the exact installation geometry.