BTU sizing for a 10×12 twin-wall greenhouse at 20°F
The gabled house is 10 ft wide and 12 ft long, with 6 ft eaves and a 2 ft roof rise. The inside target is 60°F at a 20°F outdoor design temperature.
Inputs
Results
Estimated heat output
Glazing loss adjusted by the exposure multiplier
- Exposed glazing area
- 413.24 ft²
- Heating temperature difference
- 40 °F
- Glazing U-value
- 3.5 W/m²·K
- Conduction before wind factor
- 2.99 kW
- Estimated load
- 11,717 BTU/hr
- Estimated load
- 3.43 kW
Glazing comparison
Same envelope, temperature difference and exposure for each material.
Inputs used
- Greenhouse shape
- Gable roof
- Greenhouse length
- 12 ft
- Greenhouse width
- 10 ft
- Sidewall height
- 6 ft
- Roof rise above sidewall
- 2 ft
- Indoor design temperature
- 60 °F
- Outdoor design temperature
- 20 °F
- Glazing
- Twin-wall polycarbonate
- Wind and exposure factor
- 1.15 ×
Worked calculation
- Find the exposed envelope
2 × (12 + 10) × 6 + 10 × 2 + 2 × 12 × √((10 ÷ 2)² + 2²) = 413.24 ft²
- Find the positive temperature difference
max(0, 15.56 − (-6.67)) = 22.22 °C
- Apply the U-value and exposure multiplier
3.5 × 38.392 m² × 22.222 K × 1.15 = 3,433.9 W
- Convert watts into BTU/hr
3,433.9 × 3.41214 = 11,717 BTU/hr
What the example shows
The exposed area is about 413 ft². With a 3.5 W/m²·K U-value and a 1.15 exposure factor, this model estimates about 11,717 BTU/hr.
How the model works
The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.
Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.
References
Common questions
Why is the glazing area much larger than the 120 ft² floor?
The envelope includes two sidewalls, two gable ends and two roof slopes. The floor footprint measures the level ground beneath them.
Will a 12,000 BTU/hr heater necessarily hold 60°F in the 10×12 house?
Check the delivered output, local design temperature and air leakage. A small difference between heater output and modeled loss can disappear once those are included.