Greenhouse heat loss from 240 ft² and a rated U-value
An envelope takeoff gives 240 ft² of exposed glazing with a rated U-factor of 0.50 BTU/hr·ft²·°F. The inside and outside design temperatures are 65°F and 25°F.
Inputs
Results
Estimated heat output
Glazing loss adjusted by the exposure multiplier
- Exposed glazing area
- 240 ft²
- Heating temperature difference
- 40 °F
- Glazing U-value
- 2.84 W/m²·K
- Conduction before wind factor
- 1.41 kW
- Estimated load
- 5,280 BTU/hr
- Estimated load
- 1.55 kW
Glazing comparison
Same envelope, temperature difference and exposure for each material.
Inputs used
- Greenhouse shape
- Enter exposed area
- Exposed envelope area
- 240 ft²
- Indoor design temperature
- 65 °F
- Outdoor design temperature
- 25 °F
- Glazing
- Custom rated U-value
- Rated U-value
- 0.5 BTU/hr·ft²·°F
- Wind and exposure factor
- 1.1 ×
Worked calculation
- Find the exposed envelope
Entered glazing area = 240 ft²
- Find the positive temperature difference
max(0, 18.33 − (-3.89)) = 22.22 °C
- Apply the U-value and exposure multiplier
2.839 × 22.297 m² × 22.222 K × 1.1 = 1,547.4 W
- Convert watts into BTU/hr
1,547.4 × 3.41214 = 5,280 BTU/hr
What the example shows
The base load is 4,800 BTU/hr. A 1.10 exposure multiplier gives 5,280 BTU/hr, which makes the manual-area formula easy to check by hand.
How the model works
The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.
Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.
References
Common questions
Can I enter a product R-value of 2 directly in the custom U field?
Use its reciprocal in compatible units. An R-value of 2 hr·ft²·°F/BTU corresponds to U = 0.5 BTU/hr·ft²·°F.
Should the 240 ft² include both sides of each glazing panel?
Use the area of each assembly once. U relates heat flow through the panel to the temperature difference across it.