Greenhouse heating and BTU loss calculator

Size greenhouse heat output in BTU/hr or kW from exposed glazing area, design temperature, wind allowance and glazing U-value.

Inputs

Exposed envelope
ft
ft
ft
ft
Design conditions
°F
°F
×

Use 1.00 for conduction only.

Results

Estimated heat output

11,717 BTU/hr

Glazing loss adjusted by the exposure multiplier

Exposed glazing area
413.24 ft²
Heating temperature difference
40 °F
Glazing U-value
3.5 W/m²·K
Conduction before wind factor
2.99 kW
Estimated load
11,717 BTU/hr
Estimated load
3.43 kW

Glazing comparison

Same envelope, temperature difference and exposure for each material.

Heat output by glazing materialTwin-wall polycarbonate: 11,717.01 BTU/hr. Single glass: 20,755.85 BTU/hr. Double poly film: 13,390.87 BTU/hr. Single poly film: 22,764.48 BTU/hrTwin-wall polycarbonate11,717 BTU/hrSingle glass20,756 BTU/hrDouble poly film13,391 BTU/hrSingle poly film22,764 BTU/hr

Worked calculation

  1. Find the exposed envelope

    2 × (12 + 10) × 6 + 10 × 2 + 2 × 12 × √((10 ÷ 2)² + 2²) = 413.24 ft²

  2. Find the positive temperature difference

    max(0, 15.56 − (-6.67)) = 22.22 °C

  3. Apply the U-value and exposure multiplier

    3.5 × 38.392 m² × 22.222 K × 1.15 = 3,433.9 W

  4. Convert watts into BTU/hr

    3,433.9 × 3.41214 = 11,717 BTU/hr

How the model works

The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.

Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.

References

Common questions

Is heater output the same as heater input?

The calculator estimates output delivered to the greenhouse. A fuel heater rated at 80% efficiency needs input equal to the required output divided by 0.8.

How can I account for insulated walls and glazed roofs?

Calculate U × area × ΔT separately for each envelope assembly. Add those loads and apply a consistent approach to exposure and infiltration.