Greenhouse heating and BTU loss calculator
Size greenhouse heat output in BTU/hr or kW from exposed glazing area, design temperature, wind allowance and glazing U-value.
Inputs
Results
Estimated heat output
Glazing loss adjusted by the exposure multiplier
- Exposed glazing area
- 413.24 ft²
- Heating temperature difference
- 40 °F
- Glazing U-value
- 3.5 W/m²·K
- Conduction before wind factor
- 2.99 kW
- Estimated load
- 11,717 BTU/hr
- Estimated load
- 3.43 kW
Glazing comparison
Same envelope, temperature difference and exposure for each material.
Inputs used
- Greenhouse shape
- Gable roof
- Greenhouse length
- 12 ft
- Greenhouse width
- 10 ft
- Sidewall height
- 6 ft
- Roof rise above sidewall
- 2 ft
- Indoor design temperature
- 60 °F
- Outdoor design temperature
- 20 °F
- Glazing
- Twin-wall polycarbonate
- Wind and exposure factor
- 1.15 ×
Worked calculation
- Find the exposed envelope
2 × (12 + 10) × 6 + 10 × 2 + 2 × 12 × √((10 ÷ 2)² + 2²) = 413.24 ft²
- Find the positive temperature difference
max(0, 15.56 − (-6.67)) = 22.22 °C
- Apply the U-value and exposure multiplier
3.5 × 38.392 m² × 22.222 K × 1.15 = 3,433.9 W
- Convert watts into BTU/hr
3,433.9 × 3.41214 = 11,717 BTU/hr
How the model works
The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.
Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.
References
Common questions
Is heater output the same as heater input?
The calculator estimates output delivered to the greenhouse. A fuel heater rated at 80% efficiency needs input equal to the required output divided by 0.8.
How can I account for insulated walls and glazed roofs?
Calculate U × area × ΔT separately for each envelope assembly. Add those loads and apply a consistent approach to exposure and infiltration.