Winter heat loss for a 12×24 double-poly hoop house

A semicircular hoop house is 12 ft wide and 24 ft long. It has closed ends, double poly film and a 50°F indoor target at 8°F outdoors.

Inputs

Exposed envelope
ft
ft
Design conditions
°F
°F
×

Use 1.00 for conduction only.

Results

Estimated heat output

20,077 BTU/hr

Glazing loss adjusted by the exposure multiplier

Exposed glazing area
565.49 ft²
Heating temperature difference
42 °F
Glazing U-value
4 W/m²·K
Conduction before wind factor
4.9 kW
Estimated load
20,077 BTU/hr
Estimated load
5.88 kW

Glazing comparison

Same envelope, temperature difference and exposure for each material.

Heat output by glazing materialTwin-wall polycarbonate: 17,567.32 BTU/hr. Single glass: 31,119.25 BTU/hr. Double poly film: 20,076.93 BTU/hr. Single poly film: 34,130.79 BTU/hrTwin-wall polycarbonate17,567 BTU/hrSingle glass31,119 BTU/hrDouble poly film20,077 BTU/hrSingle poly film34,131 BTU/hr

Worked calculation

  1. Find the exposed envelope

    π × 6 × (24 + 6) = 565.49 ft²

  2. Find the positive temperature difference

    max(0, 10 − (-13.33)) = 23.33 °C

  3. Apply the U-value and exposure multiplier

    4 × 52.535 m² × 23.333 K × 1.2 = 5,884 W

  4. Convert watts into BTU/hr

    5,884 × 3.41214 = 20,076.9 BTU/hr

What the example shows

The two ends and curved cover total about 565.5 ft². At a 1.20 exposure factor, the modeled load is about 20,077 BTU/hr.

How the model works

The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.

Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.

References

Common questions

How do I handle a Gothic hoop profile instead of a true semicircle?

Measure its cover arc and end areas, sum the exposed surfaces, then use the manual area setting. The semicircle preset fixes the height at half the span.

Does an uninflated gap qualify as the double-poly preset?

The thermal performance depends on the actual construction and maintained air space. Use a rated U-value for the installed assembly when available.