Single-glass 8×10 greenhouse heater load at 15°F

An 8×10 ft glass greenhouse has 5 ft eaves and a 2 ft rise. At 15°F outside and 60°F inside, the model uses a representative single-glass U-value and 1.10 exposure.

Inputs

Exposed envelope
ft
ft
ft
ft
Design conditions
°F
°F
×

Use 1.00 for conduction only.

Results

Estimated heat output

15,428 BTU/hr

Glazing loss adjusted by the exposure multiplier

Exposed glazing area
285.44 ft²
Heating temperature difference
45 °F
Glazing U-value
6.2 W/m²·K
Conduction before wind factor
4.11 kW
Estimated load
15,428 BTU/hr
Estimated load
4.52 kW

Glazing comparison

Same envelope, temperature difference and exposure for each material.

Heat output by glazing materialTwin-wall polycarbonate: 8,709.17 BTU/hr. Single glass: 15,427.67 BTU/hr. Double poly film: 9,953.34 BTU/hr. Single poly film: 16,920.67 BTU/hrTwin-wall polycarbonate8,709 BTU/hrSingle glass15,428 BTU/hrDouble poly film9,953 BTU/hrSingle poly film16,921 BTU/hr

Worked calculation

  1. Find the exposed envelope

    2 × (10 + 8) × 5 + 8 × 2 + 2 × 10 × √((8 ÷ 2)² + 2²) = 285.44 ft²

  2. Find the positive temperature difference

    max(0, 15.56 − (-9.44)) = 25 °C

  3. Apply the U-value and exposure multiplier

    6.2 × 26.518 m² × 25 K × 1.1 = 4,521.4 W

  4. Convert watts into BTU/hr

    4,521.4 × 3.41214 = 15,427.7 BTU/hr

What the example shows

The load is about 15,428 BTU/hr. Use the glazing comparison to see how covering choice affects the same envelope before considering infiltration.

How the model works

The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.

Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.

References

Common questions

Can I use the nominal single-glass preset for a draughty old house?

Use it for the glass conduction estimate. Assess leakage from doors, failed seals and loose panes separately.

Which temperature should represent a cold clear night for this 8×10 house?

Use a local outdoor design temperature appropriate to the crop risk and operating goal. A warm daytime reading is a poor winter overnight sizing basis.