Flat-roof 3 × 4 m greenhouse heating load

The rectangular house is 3 m by 4 m with 2.2 m walls. Indoor design is 14°C, outdoor design is −2°C and the wind factor is 1.00.

Inputs

Exposed envelope
m
m
m
Design conditions
°C
°C
×

Use 1.00 for conduction only.

Results

Estimated heat output

4.66 kW

Glazing loss adjusted by the exposure multiplier

Exposed glazing area
42.8 m²
Heating temperature difference
16 °C
Glazing U-value
6.8 W/m²·K
Conduction before wind factor
4.66 kW
Estimated load
15,889 BTU/hr
Estimated load
4.66 kW

Glazing comparison

Same envelope, temperature difference and exposure for each material.

Heat output by glazing materialTwin-wall polycarbonate: 2.4 kW. Single glass: 4.25 kW. Double poly film: 2.74 kW. Single poly film: 4.66 kWTwin-wall polycarbonate2.4 kWSingle glass4.25 kWDouble poly film2.74 kWSingle poly film4.66 kW

Worked calculation

  1. Find the exposed envelope

    2 × (4 + 3) × 2.2 + 4 × 3 = 42.8 m²

  2. Find the positive temperature difference

    max(0, 14 − (-2)) = 16 °C

  3. Apply the U-value and exposure multiplier

    6.8 × 42.8 m² × 16 K × 1 = 4,656.6 W

  4. Convert watts into BTU/hr

    4,656.6 × 3.41214 = 15,889.1 BTU/hr

What the example shows

There are 42.8 m² of exposed surfaces. The representative single-film U-value gives about 4.66 kW of conduction at the stated temperature difference.

How the model works

The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.

Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.

References

Common questions

Does choosing a flat roof include the floor under the 3×4 m house?

The envelope calculation includes four walls and the roof. Model slab or ground transfer separately for a complete design.

What does wind factor 1.00 mean in this greenhouse example?

It leaves the pure conduction term unchanged. It gives a reproducible baseline before applying any defensible exposure allowance.