Flat-roof 3 × 4 m greenhouse heating load
The rectangular house is 3 m by 4 m with 2.2 m walls. Indoor design is 14°C, outdoor design is −2°C and the wind factor is 1.00.
Inputs
Results
Estimated heat output
Glazing loss adjusted by the exposure multiplier
- Exposed glazing area
- 42.8 m²
- Heating temperature difference
- 16 °C
- Glazing U-value
- 6.8 W/m²·K
- Conduction before wind factor
- 4.66 kW
- Estimated load
- 15,889 BTU/hr
- Estimated load
- 4.66 kW
Glazing comparison
Same envelope, temperature difference and exposure for each material.
Inputs used
- Greenhouse shape
- Flat roof
- Greenhouse length
- 4 m
- Greenhouse width
- 3 m
- Sidewall height
- 2.2 m
- Indoor design temperature
- 14 °C
- Outdoor design temperature
- -2 °C
- Glazing
- Single poly film
- Wind and exposure factor
- 1 ×
Worked calculation
- Find the exposed envelope
2 × (4 + 3) × 2.2 + 4 × 3 = 42.8 m²
- Find the positive temperature difference
max(0, 14 − (-2)) = 16 °C
- Apply the U-value and exposure multiplier
6.8 × 42.8 m² × 16 K × 1 = 4,656.6 W
- Convert watts into BTU/hr
4,656.6 × 3.41214 = 15,889.1 BTU/hr
What the example shows
There are 42.8 m² of exposed surfaces. The representative single-film U-value gives about 4.66 kW of conduction at the stated temperature difference.
How the model works
The estimate uses U × area × temperature difference. The envelope covers roofs, walls and closed ends. The ground plane is outside this geometry model. A semicircular hoop uses radius equal to half the width.
Preset U-values are representative. Check the glazing assembly’s published U-value. Exposure is an allowance, and a full equipment sizing calculation also accounts for infiltration, ground losses, radiation and heater efficiency.
References
Common questions
Does choosing a flat roof include the floor under the 3×4 m house?
The envelope calculation includes four walls and the roof. Model slab or ground transfer separately for a complete design.
What does wind factor 1.00 mean in this greenhouse example?
It leaves the pure conduction term unchanged. It gives a reproducible baseline before applying any defensible exposure allowance.