Propagation VPD for 24°C air and 75% RH
A propagation tray is holding 24°C, 75% RH and a leaf temperature of 23°C. Use the propagation target to compare conditions at the cutting surface.
Inputs
Results
Leaf VPD
Propagation · 0.4–0.8 kPa · within band
- Air VPD
- 0.75 kPa
- Leaf temperature
- 23 °C
- Air dew point
- 19.29 °C
- Actual vapor pressure
- 2.238 kPa
- RH for this stage
- 67.3–80.7 % RH
Temperature × humidity
Cell values are leaf VPD in kPa. Select a cell to use its conditions.
Inputs used
- Air temperature
- 24 °C
- Relative humidity
- 75 % RH
- Leaf temperature offset
- -1 °C
- Growth stage
- Propagation
Worked calculation
- Find the leaf temperature
24 °C + (-1 °C) = 23 °C
- Apply the Tetens saturation equation
eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 2.9839 kPa, leaf = 2.8094 kPa.
- Find actual air vapor pressure
2.9839 × 0.75 = 2.2379 kPa
- Subtract actual pressure from saturation pressure
Air: 2.9839 − 2.2379 = 0.746 kPa. Leaf: 2.8094 − 2.2379 = 0.571 kPa.
- Invert the saturation equation for dew point
237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 19.3 °C
What the example shows
The leaf VPD is about 0.57 kPa. This example illustrates a modest evaporative demand during rooting, alongside the need to monitor media and leaf wetness.
How the model works
The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.
The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.
References
Common questions
Do a propagation dome and an open bench have the same VPD?
A dome can create a different local temperature and humidity. Put the probe inside the dome to model the cutting environment.
What is the difference between mist droplets and 75% RH?
RH measures water vapor relative to saturation. Liquid droplets on a leaf come from mist or condensation and can remain even if the measured RH is below 100%.