82°F and 55% RH under LEDs with 79°F leaves

An LED-lit room settles at 82°F and 55% RH after lights-on. Canopy leaves register 79°F, so use a −3°F offset.

Inputs

Air and leaf conditions
°F
% RH
°F

Use a negative value when leaves are cooler than the air.

Results

Leaf VPD

1.33 kPa

Flowering · 1.2–1.6 kPa · within band

Air VPD
1.68 kPa
Leaf temperature
79 °F
Air dew point
64.24 °F
Actual vapor pressure
2.052 kPa
RH for this stage
47.8–58.5 % RH

Temperature × humidity

Cell values are leaf VPD in kPa. Select a cell to use its conditions.

Leaf vapor pressure deficit heatmapSelect a condition to update the air temperature and relative humidity. Values are shown in kPa. The outline follows the nearest grid cell. Arrow keys move through this grid.% RH82°F · 55% RH · 1.33 kPaAir °F70747882869094900.010.010.020.030.040.050.06800.260.30.340.40.460.530.61700.510.580.670.770.881.011.15600.760.8711.141.311.491.7501.011.161.331.521.731.972.24401.261.441.651.892.162.452.79301.511.731.982.262.582.943.33CondensationBelow bandIn bandAbove band

Worked calculation

  1. Find the leaf temperature

    82 °F + (-3 °F) = 79 °F

  2. Apply the Tetens saturation equation

    eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 3.7313 kPa, leaf = 3.3836 kPa.

  3. Find actual air vapor pressure

    3.7313 × 0.55 = 2.0522 kPa

  4. Subtract actual pressure from saturation pressure

    Air: 3.7313 − 2.0522 = 1.679 kPa. Leaf: 3.3836 − 2.0522 = 1.331 kPa.

  5. Invert the saturation equation for dew point

    237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 64.2 °F

What the example shows

The leaf result is around 1.33 kPa, while the room-derived air result is higher. Use the measured offset instead of assuming all LED-lit leaves run cooler by the same amount.

How the model works

The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.

The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.

References

Common questions

Will changing LED fixture height preserve a −3°F leaf offset?

Measure again after changing height. The new radiant load, airflow and plant water status can change the difference between foliage and air.

Do I enter the LED heat sink temperature for leaf VPD?

Use leaf surface temperature. Fixture temperature tells you about the light hardware and does not belong in the VPD equation.