78°F and 60% RH leaf VPD with a −2°F offset

A vegetative canopy measures 78°F at 60% relative humidity. An infrared reading on a representative leaf is 76°F, so the leaf offset is −2°F.

Inputs

Air and leaf conditions
°F
% RH
°F

Use a negative value when leaves are cooler than the air.

Results

Leaf VPD

1.1 kPa

Vegetative · 0.8–1.2 kPa · within band

Air VPD
1.31 kPa
Leaf temperature
76 °F
Air dew point
62.99 °F
Actual vapor pressure
1.964 kPa
RH for this stage
56.9–69.2 % RH

Temperature × humidity

Cell values are leaf VPD in kPa. Select a cell to use its conditions.

Leaf vapor pressure deficit heatmapSelect a condition to update the air temperature and relative humidity. Values are shown in kPa. The outline follows the nearest grid cell. Arrow keys move through this grid.% RH78°F · 60% RH · 1.1 kPaAir °F66707478828690900.070.080.10.120.140.160.19800.290.340.390.450.510.590.67700.510.590.670.770.881.011.15600.730.840.961.11.261.431.63500.941.091.251.431.631.862.11401.161.341.531.7522.282.6301.381.591.822.082.382.713.08CondensationBelow bandIn bandAbove band

Worked calculation

  1. Find the leaf temperature

    78 °F + (-2 °F) = 76 °F

  2. Apply the Tetens saturation equation

    eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 3.2741 kPa, leaf = 3.0645 kPa.

  3. Find actual air vapor pressure

    3.2741 × 0.6 = 1.9645 kPa

  4. Subtract actual pressure from saturation pressure

    Air: 3.2741 − 1.9645 = 1.31 kPa. Leaf: 3.0645 − 1.9645 = 1.1 kPa.

  5. Invert the saturation equation for dew point

    237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 63 °F

What the example shows

The modeled leaf VPD is about 1.10 kPa, inside the 0.8–1.2 kPa planning band. Measure air and leaf temperature at the same time to keep that comparison meaningful.

How the model works

The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.

The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.

References

Common questions

Why does a 76°F leaf change VPD in a 78°F room?

Water vapor saturation pressure is lower at 76°F. With the same surrounding air moisture, that leaves a smaller vapor pressure difference at the leaf.

Can I use one infrared reading for the whole vegetative canopy?

Sample both lit and shaded leaves and repeat near the canopy edges. The best single offset is one that represents the plants you are trying to manage.