Dew point and condensation risk at 68°F and 90% RH

A greenhouse cools to 68°F and 90% RH overnight. A leaf near the glazing measures 64°F, below the air dew point of about 65°F.

Inputs

Air and leaf conditions
°F
% RH
°F

Use a negative value when leaves are cooler than the air.

Results

Leaf VPD

-0.07 kPa

Leaf surface is below dew point.

Air VPD
0.23 kPa
Leaf temperature
64 °F
Air dew point
64.96 °F
Actual vapor pressure
2.104 kPa
RH for this stage
35.7–52.8 % RH

Temperature × humidity

Cell values are leaf VPD in kPa. Select a cell to use its conditions.

Leaf vapor pressure deficit heatmapSelect a condition to update the air temperature and relative humidity. Values are shown in kPa. The outline follows the nearest grid cell. Arrow keys move through this grid.% RH68°F · 90% RH · -0.07 kPaAir °F56606468727680100-0.21-0.24-0.27-0.3-0.34-0.38-0.4390-0.06-0.06-0.06-0.07-0.07-0.08-0.08800.10.120.140.160.190.230.27700.250.290.340.40.460.530.62600.40.470.550.630.730.840.97500.560.650.750.8711.151.32400.710.820.951.11.271.451.67CondensationBelow bandIn bandAbove band

Worked calculation

  1. Find the leaf temperature

    68 °F + (-4 °F) = 64 °F

  2. Apply the Tetens saturation equation

    eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 2.3383 kPa, leaf = 2.0353 kPa.

  3. Find actual air vapor pressure

    2.3383 × 0.9 = 2.1045 kPa

  4. Subtract actual pressure from saturation pressure

    Air: 2.3383 − 2.1045 = 0.234 kPa. Leaf: 2.0353 − 2.1045 = -0.069 kPa.

  5. Invert the saturation equation for dew point

    237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 65 °F

What the example shows

Leaf VPD is close to −0.07 kPa. That flags possible condensation on the measured leaf even though the air sensor reads less than 100% RH.

How the model works

The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.

The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.

References

Common questions

Can 90% RH produce condensation on greenhouse leaves?

Yes. A leaf colder than the dew point can reach saturation locally even while the warmer air is below 100% RH.

Why check leaves next to the glazing after sunset?

The outer canopy may cool more sharply than the center of the room. A sample near the cold glazing can reveal a wet-leaf risk missed by a central sensor.