Flowering VPD at 80°F and 50% RH
The room is 80°F and 50% RH during the light period. A leaf reading matches the air temperature, so use a zero offset for this comparison.
Inputs
Results
Leaf VPD
Flowering · 1.2–1.6 kPa · above band
- Air VPD
- 1.75 kPa
- Leaf temperature
- 80 °F
- Air dew point
- 59.69 °F
- Actual vapor pressure
- 1.748 kPa
- RH for this stage
- 54.2–65.7 % RH
Temperature × humidity
Cell values are leaf VPD in kPa. Select a cell to use its conditions.
Inputs used
- Air temperature
- 80 °F
- Relative humidity
- 50 % RH
- Leaf temperature offset
- 0 °F
- Growth stage
- Flowering
Worked calculation
- Find the leaf temperature
80 °F + (0 °F) = 80 °F
- Apply the Tetens saturation equation
eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 3.4962 kPa, leaf = 3.4962 kPa.
- Find actual air vapor pressure
3.4962 × 0.5 = 1.7481 kPa
- Subtract actual pressure from saturation pressure
Air: 3.4962 − 1.7481 = 1.748 kPa. Leaf: 3.4962 − 1.7481 = 1.748 kPa.
- Invert the saturation equation for dew point
237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 59.7 °F
What the example shows
An unchanged leaf temperature gives 1.75 kPa. At the same temperature, a moderate increase in RH moves this example toward the 1.2–1.6 kPa band.
How the model works
The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.
The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.
References
Common questions
What if the flower canopy warms as I raise humidity?
Recalculate with the new leaf temperature as well as the new RH. A warmer leaf can offset some of the effect of a higher air humidity.
Where should I place my RH probe in an 80°F flower room?
Measure in moving air at canopy height and shield the probe from direct lamp radiation or wet spray. Check a second spot if the canopy is uneven.