Flowering VPD at 80°F and 50% RH

The room is 80°F and 50% RH during the light period. A leaf reading matches the air temperature, so use a zero offset for this comparison.

Inputs

Air and leaf conditions
°F
% RH
°F

Use a negative value when leaves are cooler than the air.

Results

Leaf VPD

1.75 kPa

Flowering · 1.2–1.6 kPa · above band

Air VPD
1.75 kPa
Leaf temperature
80 °F
Air dew point
59.69 °F
Actual vapor pressure
1.748 kPa
RH for this stage
54.2–65.7 % RH

Temperature × humidity

Cell values are leaf VPD in kPa. Select a cell to use its conditions.

Leaf vapor pressure deficit heatmapSelect a condition to update the air temperature and relative humidity. Values are shown in kPa. The outline follows the nearest grid cell. Arrow keys move through this grid.% RH80°F · 50% RH · 1.75 kPaAir °F68727680848892800.470.540.610.70.80.91.02700.70.80.921.051.191.361.54600.941.071.231.41.591.812.05501.171.341.531.751.992.262.56401.41.611.842.12.392.713.07301.641.882.152.452.793.163.59201.872.142.452.83.183.624.1CondensationBelow bandIn bandAbove band

Worked calculation

  1. Find the leaf temperature

    80 °F + (0 °F) = 80 °F

  2. Apply the Tetens saturation equation

    eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 3.4962 kPa, leaf = 3.4962 kPa.

  3. Find actual air vapor pressure

    3.4962 × 0.5 = 1.7481 kPa

  4. Subtract actual pressure from saturation pressure

    Air: 3.4962 − 1.7481 = 1.748 kPa. Leaf: 3.4962 − 1.7481 = 1.748 kPa.

  5. Invert the saturation equation for dew point

    237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 59.7 °F

What the example shows

An unchanged leaf temperature gives 1.75 kPa. At the same temperature, a moderate increase in RH moves this example toward the 1.2–1.6 kPa band.

How the model works

The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.

The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.

References

Common questions

What if the flower canopy warms as I raise humidity?

Recalculate with the new leaf temperature as well as the new RH. A warmer leaf can offset some of the effect of a higher air humidity.

Where should I place my RH probe in an 80°F flower room?

Measure in moving air at canopy height and shield the probe from direct lamp radiation or wet spray. Check a second spot if the canopy is uneven.