Vapor pressure deficit calculator
Calculate air and leaf vapor pressure deficit in kPa, find dew point and explore temperature and humidity on an interactive growth-stage heatmap.
Inputs
Results
Leaf VPD
Vegetative · 0.8–1.2 kPa · within band
- Air VPD
- 1.31 kPa
- Leaf temperature
- 76 °F
- Air dew point
- 62.99 °F
- Actual vapor pressure
- 1.964 kPa
- RH for this stage
- 56.9–69.2 % RH
Temperature × humidity
Cell values are leaf VPD in kPa. Select a cell to use its conditions.
Inputs used
- Air temperature
- 78 °F
- Relative humidity
- 60 % RH
- Leaf temperature offset
- -2 °F
- Growth stage
- Vegetative
Worked calculation
- Find the leaf temperature
78 °F + (-2 °F) = 76 °F
- Apply the Tetens saturation equation
eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 3.2741 kPa, leaf = 3.0645 kPa.
- Find actual air vapor pressure
3.2741 × 0.6 = 1.9645 kPa
- Subtract actual pressure from saturation pressure
Air: 3.2741 − 1.9645 = 1.31 kPa. Leaf: 3.0645 − 1.9645 = 1.1 kPa.
- Invert the saturation equation for dew point
237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 63 °F
How the model works
The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.
The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.
References
Common questions
How is leaf VPD different from air VPD?
Air VPD uses the saturation pressure at air temperature. Leaf VPD uses saturation pressure at leaf temperature and subtracts the actual vapor pressure of the surrounding air.
How do I read the VPD heatmap?
Each cell shows modeled leaf VPD for its air temperature and humidity with your leaf offset held constant. Select a cell to use its conditions in the calculator.