Greenhouse dew point at 72°F and 65% RH

A mixed greenhouse is 72°F at 65% RH. Use a 71°F leaf to compare the dew point margin with the leaf VPD reading.

Inputs

Air and leaf conditions
°F
% RH
°F

Use a negative value when leaves are cooler than the air.

Results

Leaf VPD

0.85 kPa

Vegetative · 0.8–1.2 kPa · within band

Air VPD
0.94 kPa
Leaf temperature
71 °F
Air dew point
59.59 °F
Actual vapor pressure
1.742 kPa
RH for this stage
51.9–66.8 % RH

Temperature × humidity

Cell values are leaf VPD in kPa. Select a cell to use its conditions.

Leaf vapor pressure deficit heatmapSelect a condition to update the air temperature and relative humidity. Values are shown in kPa. The outline follows the nearest grid cell. Arrow keys move through this grid.% RH72°F · 65% RH · 0.85 kPaAir °F60646872768084100-0.06-0.07-0.08-0.09-0.1-0.11-0.13900.110.130.150.180.210.240.27800.290.340.390.450.510.590.67700.470.540.620.710.820.941.07600.640.740.860.981.131.291.47500.820.951.091.251.431.641.864011.151.321.521.741.992.26CondensationBelow bandIn bandAbove band

Worked calculation

  1. Find the leaf temperature

    72 °F + (-1 °F) = 71 °F

  2. Apply the Tetens saturation equation

    eₛ(T) = 0.6108 × exp(17.27T ÷ (T + 237.3)), T in °C. Air = 2.68 kPa, leaf = 2.5907 kPa.

  3. Find actual air vapor pressure

    2.68 × 0.65 = 1.742 kPa

  4. Subtract actual pressure from saturation pressure

    Air: 2.68 − 1.742 = 0.938 kPa. Leaf: 2.5907 − 1.742 = 0.849 kPa.

  5. Invert the saturation equation for dew point

    237.3 × ln(eₐ ÷ 0.6108) ÷ (17.27 − ln(eₐ ÷ 0.6108)) = 59.6 °F

What the example shows

The dew point is about 59.6°F. Use that value to check colder surfaces such as glazing and exposed pipes as well as the canopy.

How the model works

The air calculation uses air saturation pressure. The leaf calculation treats the leaf surface as saturated at the measured leaf temperature and uses the same actual air vapor pressure. A negative leaf VPD flags potential condensation.

The propagation (0.4–0.8 kPa), vegetative (0.8–1.2 kPa) and flowering (1.2–1.6 kPa) bands are planning presets. Cultivar, airflow, growth stage, root-zone moisture and sensor placement can change the useful target.

References

Common questions

Does the 71°F leaf reading change the air dew point?

Air dew point uses air temperature and humidity. The leaf reading is used to compare the surface with that dew point and to calculate leaf VPD.

Can a cold irrigation pipe sweat at 72°F room temperature?

It can if its surface is below the dew point. In this example, a pipe surface under about 59.6°F is susceptible.