Lettuce DLI from 300 PPFD for 16 hours

A 2×4 ft lettuce shelf is lit for 16 hours and averages 300 µmol/m²/s. Compare that schedule to the leafy-greens planning band.

Inputs

Daily light
µmol/m²/s
h/day
mol/m²/day

Leave at zero for a room lit only by lamps.

Coverage and operating cost
ft²
µmol/J
%
W
USD/kWh
days

Results

Total daily light integral

17.28 mol/m²/day

Leafy greens · 12–17 mol/m²/day planning band

Lamp contribution
17.28 mol/m²/day
Estimated target power
114 W
Coverage per fixture at target PPFD
10.52 ft²
Whole fixtures at rated power
1
Target-power energy
54.74 kWh/month
Target-power electricity cost
8.76 USD/month
Whole-fixture electricity cost
11.52 USD/month

Crop target gauge

Illustrative range. Set a crop-specific target before choosing fixtures.

Daily light target gauge17.28 mol per square meter per day. Illustrative band: Leafy greens 12–17DLI · mol/m²/day17.28040Leafy greens 12–17

Worked calculation

  1. Integrate lamp PPFD over the photoperiod

    300 × 16 × 0.0036 = 17.28 mol/m²/day

  2. Add measured sunlight contribution

    17.28 + 0 = 17.28 mol/m²/day

  3. Convert canopy photon demand into wall power

    300 × 0.7432 m² ÷ (2.3 × 0.85) = 114.05 W

  4. Find area per fixture at target PPFD

    150 × 2.3 × 0.85 ÷ 300 = 10.52 ft²

  5. Price the scheduled energy

    0.11405 kW × 16 h × 30 days × $0.16 = $8.76 per month at target power

What the example shows

The light budget is 17.28 mol/m²/day. To model a shorter photoperiod, edit hours and check how much average PPFD would keep the same DLI.

How the model works

The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.

Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.

References

Common questions

Can I measure lettuce PPFD above the shelf with a phone lux meter?

Lux is weighted for human vision. Use a suitable quantum sensor or a spectrum-specific conversion, and sample above the leaves across the shelf.

Why use an average PPFD on a lettuce shelf?

A center reading can be brighter than the edges. A canopy average reflects the total photons landing across the crop area.