600 PPFD for 18 hours and LED wattage for a 4×4 tent
A 4×4 ft tent needs an average 600 µmol/m²/s over an 18-hour light period. The LED datasheet reports 2.5 µmol/J and estimated canopy capture is 85%.
Inputs
Results
Total daily light integral
Vegetative canopy · 20–35 mol/m²/day planning band
- Lamp contribution
- 38.88 mol/m²/day
- Estimated target power
- 419.7 W
- Coverage per fixture at target PPFD
- 17.15 ft²
- Whole fixtures at rated power
- 1
- Target-power energy
- 226.64 kWh/month
- Target-power electricity cost
- 40.8 USD/month
- Whole-fixture electricity cost
- 43.74 USD/month
Crop target gauge
Illustrative range. Set a crop-specific target before choosing fixtures.
Inputs used
- Average lamp PPFD
- 600 µmol/m²/s
- Photoperiod
- 18 h/day
- Measured sunlight DLI
- 0 mol/m²/day
- Target band
- Vegetative canopy
- Canopy area
- 16 ft²
- Fixture photon efficacy
- 2.5 µmol/J
- Light reaching canopy
- 85 %
- Power per fixture
- 450 W
- Electricity rate
- 0.18 USD/kWh
- Days lit per month
- 30 days
Worked calculation
- Integrate lamp PPFD over the photoperiod
600 × 18 × 0.0036 = 38.88 mol/m²/day
- Add measured sunlight contribution
38.88 + 0 = 38.88 mol/m²/day
- Convert canopy photon demand into wall power
600 × 1.4864 m² ÷ (2.5 × 0.85) = 419.7 W
- Find area per fixture at target PPFD
450 × 2.5 × 0.85 ÷ 600 = 17.15 ft²
- Price the scheduled energy
0.4197 kW × 18 h × 30 days × $0.18 = $40.8 per month at target power
What the example shows
That schedule produces 38.88 mol/m²/day. At the stated optical capture, about 420 W meets the average PPFD estimate. A 450 W fixture at full power costs more to run than the target-power estimate.
How the model works
The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.
Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.
References
Common questions
Is 600 PPFD over 18 hours the same DLI as 900 PPFD over 12 hours?
Both integrate to 38.88 mol/m²/day at constant PPFD. Crop response can differ because intensity and dark-period length also matter.
Why does the 4×4 canopy need more watts at lower capture?
Lower capture sends fewer emitted photons to the canopy. Additional wall power is required to deliver the same average PPFD.