600 PPFD for 18 hours and LED wattage for a 4×4 tent

A 4×4 ft tent needs an average 600 µmol/m²/s over an 18-hour light period. The LED datasheet reports 2.5 µmol/J and estimated canopy capture is 85%.

Inputs

Daily light
µmol/m²/s
h/day
mol/m²/day

Leave at zero for a room lit only by lamps.

Coverage and operating cost
ft²
µmol/J
%
W
USD/kWh
days

Results

Total daily light integral

38.88 mol/m²/day

Vegetative canopy · 20–35 mol/m²/day planning band

Lamp contribution
38.88 mol/m²/day
Estimated target power
419.7 W
Coverage per fixture at target PPFD
17.15 ft²
Whole fixtures at rated power
1
Target-power energy
226.64 kWh/month
Target-power electricity cost
40.8 USD/month
Whole-fixture electricity cost
43.74 USD/month

Crop target gauge

Illustrative range. Set a crop-specific target before choosing fixtures.

Daily light target gauge38.88 mol per square meter per day. Illustrative band: Vegetative canopy 20–35DLI · mol/m²/day38.88044Vegetative canopy 20–35

Worked calculation

  1. Integrate lamp PPFD over the photoperiod

    600 × 18 × 0.0036 = 38.88 mol/m²/day

  2. Add measured sunlight contribution

    38.88 + 0 = 38.88 mol/m²/day

  3. Convert canopy photon demand into wall power

    600 × 1.4864 m² ÷ (2.5 × 0.85) = 419.7 W

  4. Find area per fixture at target PPFD

    450 × 2.5 × 0.85 ÷ 600 = 17.15 ft²

  5. Price the scheduled energy

    0.4197 kW × 18 h × 30 days × $0.18 = $40.8 per month at target power

What the example shows

That schedule produces 38.88 mol/m²/day. At the stated optical capture, about 420 W meets the average PPFD estimate. A 450 W fixture at full power costs more to run than the target-power estimate.

How the model works

The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.

Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.

References

Common questions

Is 600 PPFD over 18 hours the same DLI as 900 PPFD over 12 hours?

Both integrate to 38.88 mol/m²/day at constant PPFD. Crop response can differ because intensity and dark-period length also matter.

Why does the 4×4 canopy need more watts at lower capture?

Lower capture sends fewer emitted photons to the canopy. Additional wall power is required to deliver the same average PPFD.