Monthly LED electricity cost for a 5×5 growing area

A 25 ft² canopy runs at 500 µmol/m²/s for 18 hours per day across a 31-day billing period. Electricity costs $0.27/kWh.

Inputs

Daily light
µmol/m²/s
h/day
mol/m²/day

Leave at zero for a room lit only by lamps.

Coverage and operating cost
ft²
µmol/J
%
W
USD/kWh
days

Results

Total daily light integral

32.4 mol/m²/day

Vegetative canopy · 20–35 mol/m²/day planning band

Lamp contribution
32.4 mol/m²/day
Estimated target power
460.8 W
Coverage per fixture at target PPFD
27.13 ft²
Whole fixtures at rated power
1
Target-power energy
257.14 kWh/month
Target-power electricity cost
69.43 USD/month
Whole-fixture electricity cost
75.33 USD/month

Crop target gauge

Illustrative range. Set a crop-specific target before choosing fixtures.

Daily light target gauge32.4 mol per square meter per day. Illustrative band: Vegetative canopy 20–35DLI · mol/m²/day32.4044Vegetative canopy 20–35

Worked calculation

  1. Integrate lamp PPFD over the photoperiod

    500 × 18 × 0.0036 = 32.4 mol/m²/day

  2. Add measured sunlight contribution

    32.4 + 0 = 32.4 mol/m²/day

  3. Convert canopy photon demand into wall power

    500 × 2.3226 m² ÷ (2.8 × 0.9) = 460.83 W

  4. Find area per fixture at target PPFD

    500 × 2.8 × 0.9 ÷ 500 = 27.13 ft²

  5. Price the scheduled energy

    0.46083 kW × 18 h × 31 days × $0.27 = $69.43 per month at target power

What the example shows

At 2.8 µmol/J and 90% canopy capture, the modeled 461 W target costs about $69.43 during the billing period. Compare this with actual fixture draw and dimming settings.

How the model works

The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.

Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.

References

Common questions

Can I use a time-of-use electricity rate for the 5×5 example?

Use a weighted rate for the fixture’s on-hours, or calculate energy separately for off-peak and peak periods and total the costs.

Does the lighting cost include fans or a dehumidifier?

Add each device separately from its wall power and run time. This calculation includes the grow light schedule only.