Monthly LED electricity cost for a 5×5 growing area
A 25 ft² canopy runs at 500 µmol/m²/s for 18 hours per day across a 31-day billing period. Electricity costs $0.27/kWh.
Inputs
Results
Total daily light integral
Vegetative canopy · 20–35 mol/m²/day planning band
- Lamp contribution
- 32.4 mol/m²/day
- Estimated target power
- 460.8 W
- Coverage per fixture at target PPFD
- 27.13 ft²
- Whole fixtures at rated power
- 1
- Target-power energy
- 257.14 kWh/month
- Target-power electricity cost
- 69.43 USD/month
- Whole-fixture electricity cost
- 75.33 USD/month
Crop target gauge
Illustrative range. Set a crop-specific target before choosing fixtures.
Inputs used
- Average lamp PPFD
- 500 µmol/m²/s
- Photoperiod
- 18 h/day
- Measured sunlight DLI
- 0 mol/m²/day
- Target band
- Vegetative canopy
- Canopy area
- 25 ft²
- Fixture photon efficacy
- 2.8 µmol/J
- Light reaching canopy
- 90 %
- Power per fixture
- 500 W
- Electricity rate
- 0.27 USD/kWh
- Days lit per month
- 31 days
Worked calculation
- Integrate lamp PPFD over the photoperiod
500 × 18 × 0.0036 = 32.4 mol/m²/day
- Add measured sunlight contribution
32.4 + 0 = 32.4 mol/m²/day
- Convert canopy photon demand into wall power
500 × 2.3226 m² ÷ (2.8 × 0.9) = 460.83 W
- Find area per fixture at target PPFD
500 × 2.8 × 0.9 ÷ 500 = 27.13 ft²
- Price the scheduled energy
0.46083 kW × 18 h × 31 days × $0.27 = $69.43 per month at target power
What the example shows
At 2.8 µmol/J and 90% canopy capture, the modeled 461 W target costs about $69.43 during the billing period. Compare this with actual fixture draw and dimming settings.
How the model works
The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.
Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.
References
Common questions
Can I use a time-of-use electricity rate for the 5×5 example?
Use a weighted rate for the fixture’s on-hours, or calculate energy separately for off-peak and peak periods and total the costs.
Does the lighting cost include fans or a dehumidifier?
Add each device separately from its wall power and run time. This calculation includes the grow light schedule only.