Grow light coverage at 400 PPFD in a 3×3 area
A 3×3 ft bench runs a 12-hour lighting schedule at 400 µmol/m²/s. The selected fixture is rated 300 W and 2.4 µmol/J, with 80% capture.
Inputs
Results
Total daily light integral
Culinary herbs · 12–20 mol/m²/day planning band
- Lamp contribution
- 17.28 mol/m²/day
- Estimated target power
- 174.2 W
- Coverage per fixture at target PPFD
- 15.5 ft²
- Whole fixtures at rated power
- 1
- Target-power energy
- 62.71 kWh/month
- Target-power electricity cost
- 10.66 USD/month
- Whole-fixture electricity cost
- 18.36 USD/month
Crop target gauge
Illustrative range. Set a crop-specific target before choosing fixtures.
Inputs used
- Average lamp PPFD
- 400 µmol/m²/s
- Photoperiod
- 12 h/day
- Measured sunlight DLI
- 0 mol/m²/day
- Target band
- Culinary herbs
- Canopy area
- 9 ft²
- Fixture photon efficacy
- 2.4 µmol/J
- Light reaching canopy
- 80 %
- Power per fixture
- 300 W
- Electricity rate
- 0.17 USD/kWh
- Days lit per month
- 30 days
Worked calculation
- Integrate lamp PPFD over the photoperiod
400 × 12 × 0.0036 = 17.28 mol/m²/day
- Add measured sunlight contribution
17.28 + 0 = 17.28 mol/m²/day
- Convert canopy photon demand into wall power
400 × 0.8361 m² ÷ (2.4 × 0.8) = 174.19 W
- Find area per fixture at target PPFD
300 × 2.4 × 0.8 ÷ 400 = 15.5 ft²
- Price the scheduled energy
0.17419 kW × 12 h × 30 days × $0.17 = $10.66 per month at target power
What the example shows
This example estimates 174 W at the target and about 15.5 ft² of theoretical coverage at rated output. Use the fixture map to confirm how evenly it can light the actual bench.
How the model works
The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.
Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.
References
Common questions
Does a 300 W fixture rated for 15.5 ft² light the corners equally?
The coverage estimate divides delivered photons by target PPFD. Compare a fixture map or measured edge and corner points to see whether distribution meets the target.
How do I estimate this light’s cost after dimming?
Measure actual power at the wall once dimmed and multiply kW by running hours and the utility rate. The target-power output is a planning estimate.