Grow light coverage at 400 PPFD in a 3×3 area

A 3×3 ft bench runs a 12-hour lighting schedule at 400 µmol/m²/s. The selected fixture is rated 300 W and 2.4 µmol/J, with 80% capture.

Inputs

Daily light
µmol/m²/s
h/day
mol/m²/day

Leave at zero for a room lit only by lamps.

Coverage and operating cost
ft²
µmol/J
%
W
USD/kWh
days

Results

Total daily light integral

17.28 mol/m²/day

Culinary herbs · 12–20 mol/m²/day planning band

Lamp contribution
17.28 mol/m²/day
Estimated target power
174.2 W
Coverage per fixture at target PPFD
15.5 ft²
Whole fixtures at rated power
1
Target-power energy
62.71 kWh/month
Target-power electricity cost
10.66 USD/month
Whole-fixture electricity cost
18.36 USD/month

Crop target gauge

Illustrative range. Set a crop-specific target before choosing fixtures.

Daily light target gauge17.28 mol per square meter per day. Illustrative band: Culinary herbs 12–20DLI · mol/m²/day17.28040Culinary herbs 12–20

Worked calculation

  1. Integrate lamp PPFD over the photoperiod

    400 × 12 × 0.0036 = 17.28 mol/m²/day

  2. Add measured sunlight contribution

    17.28 + 0 = 17.28 mol/m²/day

  3. Convert canopy photon demand into wall power

    400 × 0.8361 m² ÷ (2.4 × 0.8) = 174.19 W

  4. Find area per fixture at target PPFD

    300 × 2.4 × 0.8 ÷ 400 = 15.5 ft²

  5. Price the scheduled energy

    0.17419 kW × 12 h × 30 days × $0.17 = $10.66 per month at target power

What the example shows

This example estimates 174 W at the target and about 15.5 ft² of theoretical coverage at rated output. Use the fixture map to confirm how evenly it can light the actual bench.

How the model works

The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.

Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.

References

Common questions

Does a 300 W fixture rated for 15.5 ft² light the corners equally?

The coverage estimate divides delivered photons by target PPFD. Compare a fixture map or measured edge and corner points to see whether distribution meets the target.

How do I estimate this light’s cost after dimming?

Measure actual power at the wall once dimmed and multiply kW by running hours and the utility rate. The target-power output is a planning estimate.