Add 200 PPFD to 8 mol of greenhouse sunlight DLI

A winter glazing measurement gives 8 mol/m²/day of sunlight at plant height. The lamps add about 200 µmol/m²/s for 16 hours across 20 ft².

Inputs

Daily light
µmol/m²/s
h/day
mol/m²/day

Leave at zero for a room lit only by lamps.

Coverage and operating cost
ft²
µmol/J
%
W
USD/kWh
days

Results

Total daily light integral

19.52 mol/m²/day

Culinary herbs · 12–20 mol/m²/day planning band

Lamp contribution
11.52 mol/m²/day
Estimated target power
174.9 W
Coverage per fixture at target PPFD
22.87 ft²
Whole fixtures at rated power
1
Target-power energy
83.94 kWh/month
Target-power electricity cost
15.11 USD/month
Whole-fixture electricity cost
17.28 USD/month

Crop target gauge

Illustrative range. Set a crop-specific target before choosing fixtures.

Daily light target gauge19.52 mol per square meter per day. Illustrative band: Culinary herbs 12–20DLI · mol/m²/day19.52040Culinary herbs 12–20

Worked calculation

  1. Integrate lamp PPFD over the photoperiod

    200 × 16 × 0.0036 = 11.52 mol/m²/day

  2. Add measured sunlight contribution

    11.52 + 8 = 19.52 mol/m²/day

  3. Convert canopy photon demand into wall power

    200 × 1.8581 m² ÷ (2.5 × 0.85) = 174.88 W

  4. Find area per fixture at target PPFD

    200 × 2.5 × 0.85 ÷ 200 = 22.87 ft²

  5. Price the scheduled energy

    0.17488 kW × 16 h × 30 days × $0.18 = $15.11 per month at target power

What the example shows

The lamps add 11.52 mol/m²/day, yielding 19.52 from both sources. Use the sunlight-only reading to avoid counting lamp photons twice.

How the model works

The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.

Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.

References

Common questions

Does it matter if the supplemental lamps overlap daylight?

For total DLI, simultaneous photon contributions can be added. Use separate lamp and sunlight estimates and check peak intensity during overlap.

Where do I measure the 8 mol sunlight DLI?

Measure under the glazing at crop height. Outdoor DLI misses the transmission losses from the glazing and greenhouse frame.