750 PPFD for 12 hours on a fruiting canopy
A 16 ft² fruiting canopy is planned for 750 µmol/m²/s over 12 hours. The proposed LED delivers 2.7 µmol/J at 90% assumed capture.
Inputs
Results
Total daily light integral
Fruiting canopy · 25–35 mol/m²/day planning band
- Lamp contribution
- 32.4 mol/m²/day
- Estimated target power
- 458.8 W
- Coverage per fixture at target PPFD
- 17.44 ft²
- Whole fixtures at rated power
- 1
- Target-power energy
- 165.16 kWh/month
- Target-power electricity cost
- 41.29 USD/month
- Whole-fixture electricity cost
- 45 USD/month
Crop target gauge
Illustrative range. Set a crop-specific target before choosing fixtures.
Inputs used
- Average lamp PPFD
- 750 µmol/m²/s
- Photoperiod
- 12 h/day
- Measured sunlight DLI
- 0 mol/m²/day
- Target band
- Fruiting canopy
- Canopy area
- 16 ft²
- Fixture photon efficacy
- 2.7 µmol/J
- Light reaching canopy
- 90 %
- Power per fixture
- 500 W
- Electricity rate
- 0.25 USD/kWh
- Days lit per month
- 30 days
Worked calculation
- Integrate lamp PPFD over the photoperiod
750 × 12 × 0.0036 = 32.4 mol/m²/day
- Add measured sunlight contribution
32.4 + 0 = 32.4 mol/m²/day
- Convert canopy photon demand into wall power
750 × 1.4864 m² ÷ (2.7 × 0.9) = 458.78 W
- Find area per fixture at target PPFD
500 × 2.7 × 0.9 ÷ 750 = 17.44 ft²
- Price the scheduled energy
0.45878 kW × 12 h × 30 days × $0.25 = $41.29 per month at target power
What the example shows
The resulting DLI is 32.4 mol/m²/day. This example needs about 459 W at target output. Compare the predicted light dose with the specific cultivar and production stage.
How the model works
The 0.0036 factor converts micromoles per second over an hour into moles per day. Use average canopy PPFD for an even lamp schedule. For variable daylight, record the sunlight DLI separately and add it once.
Photon efficacy describes fixture output per watt of electrical input. The canopy capture percentage models optical and edge losses. Mounting height, dimming, spacing and reflection affect the delivered PPFD. Check a fixture map or measure several locations across the canopy.
References
Common questions
What if a fruiting canopy gets less PPFD below the upper leaves?
Record measurements at the heights relevant to your crop. The top-canopy DLI is a point-of-reference and does not describe the light in shaded layers.
Does a 12-hour day automatically suit every fruiting variety?
Photoperiod response depends on the species and cultivar. Treat the hours as a lighting schedule input and follow crop-specific guidance on day length.