Large Grade 5 UNC proof load

A 1-1/4-7 screw uses the lower proof strength specified for large Grade 5 fasteners.

Input units
Load fraction 0.21214
Bolt tension 217,090 N
Clamp force 127,090 N
Separation 251,310 N

Anatomy

Bolt extension and clamp release

Edit inputs
Bolt extension and clamp releaseSchematic view with the current loads and dimensions. JOINT SECTIONJOINT FORCEExternal pull PAxial displacementPreload Fᵢ198,000 NBolt Fᵦ217,100 NClamp Fₘ127,100 N

Screening margins

Within screen
  • Separation90,000 N / 251,300 N
    Within screen
  • Bolt proof load217,100 N / 319,000 N
    Within screen

Calculated values

Bolt load fraction C0.21214
Peak bolt tension Fᵦ217,090 N
Remaining clamp Fₘ127,090 N
External separation load Pₛₑₚ251,310 N
Tensile stress area Aₜ625.23 mm²
Bolt proof strength Sₚ510.21 MPa
Axial bolt stiffness kᵦ2.0445e6 N/mm
Axial member stiffness kₘ7.5931e6 N/mm
Linear clamp reserve127,090 N
Bolt proof load319,000 N
Separation factor n₀2.7924 ×
Proof factor nₚ1.4694 ×
Cycle mean tensile stress—
Alternating tensile stress—
Nominal Goodman factor—

Starting result

The grade preset changes with diameter, so use the calculated proof strength for this size.

Bolt proof strength Sₚ
510.21 MPa
Tensile stress area Aₜ
625.23 mm²
Proof factor nₚ
1.4694 ×

Model and assumptions

C = kᵦ/(kᵦ+kₘ) · Fᵦ = Fᵢ+CP · Fₘ = Fᵢ−(1−C)P before separation

Centered axial tension with unit load introduction. The estimate uses bolt thread and shank compliance and two symmetric 30° member frusta. After separation the bolt carries the full load and retained clamp is zero.

References and calculation method

Worked examples

Open the standard calculator