ASME V Article 4 · AWS D1.1
UT Angle-Beam Skip Distance
Locate a shear-wave reflector from its sound path. Calculate skip distance, beam leg and true depth for a flat weld or a circumferential pipe scan.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 13.5mm
- Surface dist.
- 63.22mm
- Half skip
- 43.301mm
- Full skip
- 86.603mm
Leg 2
Surface distance starts at the beam exit point.
- Active leg / chord
- 2
- One leg or chord sound path
- 50mm
- Flat-plate full skip reference
- 86.603mm
- Pulse-echo round-trip time
- 45.201µs
- AWS distance correction
- 3.748dB
- Max. angle reaching pipe ID
- —
- OD-only chord arc advance
- —
- Pipe OD circumference
- —
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references
Worked examples
Open a setup to inspect its inputs, then try your own values.