ASME V Article 4 · AWS D1.1

OD-only chord in a small thick-wall pipe

A 60° shear beam enters the outside of a 114.3 mm OD pipe with an 18 mm wall.

Reading the result. The selected angle misses the inside wall. The geometry returns a chord path without assigning an ID skip.

Setup

Part geometry

mm
mm
Greater than twice wall thickness.

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
6.3551mm
Surface dist.
42.889mm
Half skip
—
Full skip
—
Beam misses the ID

Shows the OD-to-OD chord and radial depth. An ID half or full skip is unavailable.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapUnfolded OD arcOD chord progress69.991%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
1
One leg or chord sound path
57.15mm
Flat-plate full skip reference
62.354mm
Pulse-echo round-trip time
24.768µs
AWS distance correction
1.1496dB
Max. angle reaching pipe ID
43.239°
OD-only chord arc advance
59.847mm
Pipe OD circumference
359.08mm

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references