ASME V Article 4 · AWS D1.1

AWS distance correction at a 4 in sound path

A structural weld worksheet uses a 4 in one-way path and the inch-pound AWS distance correction convention.

Reading the result. Subtract the first inch before applying 2 dB per inch. This gives a 6 dB distance term before indication rating.

Setup

Part geometry

mm

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
50.8mm
Surface dist.
87.988mm
Half skip
87.988mm
Full skip
175.98mm
Leg 1

Surface distance starts at the beam exit point.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapFlat sectionActive leg progress100%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
1
One leg or chord sound path
101.6mm
Flat-plate full skip reference
175.98mm
Pulse-echo round-trip time
62.91µs
AWS distance correction
6dB
Max. angle reaching pipe ID
—
OD-only chord arc advance
—
Pipe OD circumference
—

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references