ASME V Article 4 · AWS D1.1
AWS distance correction at a 4 in sound path
A structural weld worksheet uses a 4 in one-way path and the inch-pound AWS distance correction convention.
Reading the result. Subtract the first inch before applying 2 dB per inch. This gives a 6 dB distance term before indication rating.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 50.8mm
- Surface dist.
- 87.988mm
- Half skip
- 87.988mm
- Full skip
- 175.98mm
Leg 1
Surface distance starts at the beam exit point.
- Active leg / chord
- 1
- One leg or chord sound path
- 101.6mm
- Flat-plate full skip reference
- 175.98mm
- Pulse-echo round-trip time
- 62.91µs
- AWS distance correction
- 6dB
- Max. angle reaching pipe ID
- —
- OD-only chord arc advance
- —
- Pipe OD circumference
- —
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references