ASME V Article 4 · AWS D1.1

Curvature correction on a 200 mm OD pipe

A 45° beam sees a 35 mm sound path in a circumferential scan of a 20 mm wall. Pipe OD is 200 mm.

Reading the result. The pipe-corrected OD surface projection is about 31.74 mm. A flat-plate projection would be about 24.75 mm.

Setup

Part geometry

mm
mm
Greater than twice wall thickness.

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
19.188mm
Surface dist.
31.736mm
Half skip
29.87mm
Full skip
59.741mm
Leg 2

Depth is radial from OD. Surface distance follows the OD arc.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapUnfolded OD arcActive leg progress5.1237%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
2
One leg or chord sound path
33.294mm
Flat-plate full skip reference
40mm
Pulse-echo round-trip time
21.672µs
AWS distance correction
0.75591dB
Max. angle reaching pipe ID
53.13°
OD-only chord arc advance
—
Pipe OD circumference
628.32mm

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references