ASME V Article 4 · AWS D1.1

60° shear wave in a pressure vessel seam

A 25 mm carbon-steel seam returns an indication at a one-way sound path of 73 mm. The probe is set to 60°.

Reading the result. The first backwall contact occurs at 50 mm of sound path. The return leg places the indication 13.5 mm below the reference surface.

Setup

Part geometry

mm

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
13.5mm
Surface dist.
63.22mm
Half skip
43.301mm
Full skip
86.603mm
Leg 2

Surface distance starts at the beam exit point.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapFlat sectionActive leg progress46%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
2
One leg or chord sound path
50mm
Flat-plate full skip reference
86.603mm
Pulse-echo round-trip time
45.201µs
AWS distance correction
3.748dB
Max. angle reaching pipe ID
—
OD-only chord arc advance
—
Pipe OD circumference
—

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references