ASME V Article 4 · AWS D1.1
Circumferential return leg in a large OD pipe
A 304.8 mm OD pipe has a 12.7 mm wall. A 45° inspection records a 26 mm path.
Reading the result. The first bounce is beyond 18.86 mm of sound path. Read the radial indication depth at the measured return time.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 8.0533mm
- Surface dist.
- 20.387mm
- Half skip
- 14.573mm
- Full skip
- 29.146mm
Leg 2
Depth is radial from OD. Surface distance follows the OD arc.
- Active leg / chord
- 2
- One leg or chord sound path
- 18.863mm
- Flat-plate full skip reference
- 25.4mm
- Pulse-echo round-trip time
- 16.099µs
- AWS distance correction
- 0.047244dB
- Max. angle reaching pipe ID
- 66.444°
- OD-only chord arc advance
- —
- Pipe OD circumference
- 957.56mm
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references