ASME V Article 4 · AWS D1.1

45° midwall reflector in ½ in plate

A weld mock-up uses ½ in plate with a reference reflector at midwall. A 45° wedge produces a 0.354 in sound path.

Reading the result. At 45°, the surface projection and depth match on the first leg. Use beam-exit position as the surface-distance origin.

Setup

Part geometry

mm

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
6.35mm
Surface dist.
6.35mm
Half skip
12.7mm
Full skip
25.4mm
Leg 1

Surface distance starts at the beam exit point.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapFlat sectionActive leg progress50%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
1
One leg or chord sound path
17.961mm
Flat-plate full skip reference
25.4mm
Pulse-echo round-trip time
5.5605µs
AWS distance correction
0dB
Max. angle reaching pipe ID
—
OD-only chord arc advance
—
Pipe OD circumference
—

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references