ASME V Article 4 · AWS D1.1
45° midwall reflector in ½ in plate
A weld mock-up uses ½ in plate with a reference reflector at midwall. A 45° wedge produces a 0.354 in sound path.
Reading the result. At 45°, the surface projection and depth match on the first leg. Use beam-exit position as the surface-distance origin.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 6.35mm
- Surface dist.
- 6.35mm
- Half skip
- 12.7mm
- Full skip
- 25.4mm
Leg 1
Surface distance starts at the beam exit point.
- Active leg / chord
- 1
- One leg or chord sound path
- 17.961mm
- Flat-plate full skip reference
- 25.4mm
- Pulse-echo round-trip time
- 5.5605µs
- AWS distance correction
- 0dB
- Max. angle reaching pipe ID
- —
- OD-only chord arc advance
- —
- Pipe OD circumference
- —
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references