ASME V Article 4 · AWS D1.1
Third-leg echo in a thin fabrication weld
A 10 mm plate is examined with a 60° wedge. A late indication has a one-way path of 47 mm.
Reading the result. The ray has already made one full skip. The third-leg solution places the reflector at 3.5 mm depth.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 3.5mm
- Surface dist.
- 40.703mm
- Half skip
- 17.321mm
- Full skip
- 34.641mm
Leg 3+ · pass 3
Surface distance starts at the beam exit point.
- Active leg / chord
- 3
- One leg or chord sound path
- 20mm
- Flat-plate full skip reference
- 34.641mm
- Pulse-echo round-trip time
- 29.102µs
- AWS distance correction
- 1.7008dB
- Max. angle reaching pipe ID
- —
- OD-only chord arc advance
- —
- Pipe OD circumference
- —
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references