Reference
Methods & sources
Equations, assumptions, and model limits for each worksheet.
Common calculation basis
Calculations use SI values internally and standard gravity of 9.80665 m/s². Fresh water is represented at 1,000 kg/m³. US hydraulic values use the international foot, mechanical horsepower and pound-force.
Positive stationing points downstream. Gravity-dam moments are summed about the toe. Default empirical coefficients represent the stated geometries and should be checked against project conditions.
Normal & Critical Depth
Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)
Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.
Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.
Hydraulic Jump & Stilling Basin
y₂/y₁ = [√(1 + 8 Fr₁²) − 1]/2 · ΔE = (y₂ − y₁)³/(4 y₁ y₂)
The Bélanger relation balances momentum across a jump in a horizontal rectangular channel. The basin screen uses EM 25 Figure 12 and selects Type III at Fr₁ ≥ 4.5 only within the 50 ft/s and 200 cfs/ft screens.
Verify tailwater, waves, appurtenances and cavitation at the full operating range. Chart lengths are preliminary geometric estimates.
Weir & Parshall Flume Flow
Qfree ∝ H₁ⁿ · Qsub / Qfree = [1 − (H₂/H₁)ⁿ]⁰·³⁸⁵
Francis subtracts 0.1H₁ per contracted end. Kindsvater–Shen uses an angle-dependent effective coefficient and head correction. Parshall sizes use the USBR Table 8-6 calibration in feet and cfs.
The 60% weir marker is a comparison screen. Use the USBR correction charts when Hᵦ/Hₐ exceeds 70% for these Parshall sizes. Check approach conditions, nappe ventilation and calibration limits.
Ogee Spillway & Sluice Gate
Qogee = C L Hₑ³ᐟ² · X¹·⁸⁵ = 2 Hᵈ⁰·⁸⁵ Y · y₂ = C꜀ a
The vertical-face ogee coefficient uses rounded readings from Design of Small Dams Figures 9-23 and 9-24. The gate compares tailwater against the free jet’s conjugate depth and switches to a continuous differential-head relation.
Ogee overflow assumes unimpeded discharge. Very low or high heads, pier geometry and downstream suppression require additional checks. Confirm actual gate ratings against field or model data.
Backwater / GVF Profile
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Gravity Dam Stability
FSs = (μΣV + c B w)/ΣH · e = B/2 − Mnet/ΣV · σ = ΣV/(Bw) (1 ± 6e/B)
A vertical upstream face and a straight downstream batter define the cross section. The solver integrates piecewise linear uplift and includes tailwater’s horizontal and vertical components. Positive eccentricity points downstream.
Kernel and force balance are initial screens for a single load case. Verify regulatory load combinations, drain performance, material strengths and foundation response with qualified dam-safety review.
Under-Seepage & Piping
q = k ΔH Nf/Nd · Cw = (ΣLₕ/3 + ΣLᵥ)/ΔH · FS = [(Gₛ − 1)/(1 + e)] / iₑ
The last equipotential drop divided by its local spacing estimates the exit gradient. Lane’s method assigns a one-third weight to horizontal paths and full weight to vertical paths.
The USBR 4.0 exit-gradient screen is for cohesionless quick conditions in new or remedial dam work. Filters, uplift, stratification, anisotropy and concentrated leakage require separate checks.
Shields Motion & Pier Scour
τ₀ = ρg Rₕ S₀ · θ = τ₀/[ρ (Gₛ − 1)g d₅₀] · yₛ/y₁ = 2 K₁ K₂ K₃ (a/y₁)⁰·⁶⁵ Fr₁⁰·⁴³
The sediment mode compares applied Shields stress with the Soulsby–Whitehouse critical curve. The pier mode applies HEC-18 Equation 7.1 and the angle and nose-factor rules. The aligned rounded-pier rule of thumb is shown alongside raw CSU scour.
Treat these estimates as local screening results. The pier mode needs a separate evaluation of contraction, degradation, debris, complex foundations and cohesive or rock beds.
Source register
- Open-Channel HydraulicsVen Te Chow, 1959 · Chapters 4, 6, 7 and 10 https://books.google.com/books?id=OwZSAAAAMAAJ
- Hydraulic Design of Stilling Basins and Energy DissipatorsUSBR Engineering Monograph 25 · Figure 12 and Sections 2–4 https://www.usbr.gov/tsc/techreferences/hydraulics_lab/pubs/EM/EM25.pdf
- Design of Small DamsUSBR, 3rd edition · Chapters 8 and 9, Figures 9-23 and 9-24 https://www.usbr.gov/tsc/techreferences/mands/mands-pdfs/SmallDams.pdf
- General Spillway Design ConsiderationsUSBR Design Standard 14, Chapter 3 · Ogee crest design head and design checks https://www.usbr.gov/tsc/techreferences/designstandards-datacollectionguides/finalds-pdfs/DS14-3wMIR.pdf
- Water Measurement ManualUSBR, Chapter 7 · Free-flow weir ratings and installation conditions https://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_01.html
- V-Notch Weirs of Any AngleUSBR Water Measurement Manual §7-7 · Kindsvater–Shen and Figure 7-6 https://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_07.html
- Parshall FlumesUSBR Water Measurement Manual §8-10 · Free-flow Table 8-6 and submerged correction Figure 8-16 https://www.usbr.gov/tsc/techreferences/mands/wmm/chap08_10.html
- Submerged Rectangular OrificesUSBR Water Measurement Manual §9-5 · Differential-head relation https://www.usbr.gov/tsc/techreferences/mands/wmm/chap09_05.html
- Gravity Dam DesignUSACE EM 1110-2-2200 · Chapters 3 and 4 https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-2200.pdf
- SeepageUSBR Design Standards No. 13, Chapter 8 · Exit-gradient evaluation https://www.usbr.gov/tsc/techreferences/designstandards-datacollectionguides/finalds-pdfs/DS13-8.pdf
- Internal Erosion Risks for Embankments and FoundationsUSBR/USACE Best Practices D-6 · Appendix E https://www.usbr.gov/damsafety/risk/BestPractices/Chapters/D6-InternalErosionRisksForEmbankmentsAndFoundationsWithAppendices.pdf
- Critical Thresholds for Transport and ErosionUSACE HEC-RAS sediment technical reference · Soulsby and Whitehouse (1997) https://www.hec.usace.army.mil/confluence/rasdocs/d2sd/ras2dsedtr/6.5/model-description/critical-thresholds-for-transport-and-erosion
- Evaluating Scour at BridgesFHWA HEC-18, 5th edition · Chapter 7, Equation 7.1 and Tables 7.1–7.3 https://www.govinfo.gov/content/pkg/GOVPUB-TD2-PURL-gpo161209/pdf/GOVPUB-TD2-PURL-gpo161209.pdf