Channels

Manning Normal & Critical Depth Calculator

Solve normal and critical depths in trapezoidal, rectangular and triangular channels. Compare Froude number, specific energy and section efficiency.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 1.02445 m, Critical depth: 0.654781 m, Froude: 0.479121, Specific energy: 1.11841 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH1.0245 mCRITICAL DEPTH0.65478 mFROUDE0.47912SPECIFIC E1.1184 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.47912

Calculation details

Section shape
Trapezoidal
Wetted area
8.34409 m²
Water surface width
10.1938 m
Wetted perimeter
10.6775 m
Hydraulic radius
0.781464 m
Mean velocity
1.35746 m/s
Minimum specific energy
0.932977 m
Critical slope
0.00780654
Efficient bottom width
0.867402 m
Efficient depth
1.83719 m
Conveyance gain
11.3805%

Calculation method

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.

Worked examples

Open a case to load its inputs and interpretation.

Share worksheet