Worked example

Concrete rectangular drain

A 1.8 m concrete stormwater drain carries 4.6 m³/s with square corners and a surveyed 0.35% invert slope.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 0.996368 m, Critical depth: 0.873273 m, Froude: 0.820532, Specific energy: 1.33178 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH0.99637 mCRITICAL DEPTH0.87327 mFROUDE0.82053SPECIFIC E1.3318 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.82053

Calculation details

Section shape
Rectangular
Wetted area
1.79346 m²
Water surface width
1.8 m
Wetted perimeter
3.79274 m
Hydraulic radius
0.472868 m
Mean velocity
2.56487 m/s
Minimum specific energy
1.30991 m
Critical slope
0.00496711
Efficient bottom width
1.89392 m
Efficient depth
0.946959 m
Conveyance gain
0.0862273%

Interpreting this example

Keep z at zero for vertical walls. Compare the computed critical depth with the normal depth before locating a grade transition.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet