Worked example

Efficient earth-channel section

Compare an existing 6 m bottom with the hydraulically efficient cross section at a fixed 2H:1V side slope and 9.5 m³/s.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 0.955465 m, Critical depth: 0.592206 m, Froude: 0.457506, Specific energy: 1.03601 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH0.95547 mCRITICAL DEPTH0.59221 mFROUDE0.45751SPECIFIC E1.036 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.45751

Calculation details

Section shape
Trapezoidal
Wetted area
7.55862 m²
Water surface width
9.82186 m
Wetted perimeter
10.273 m
Hydraulic radius
0.735777 m
Mean velocity
1.25684 m/s
Minimum specific energy
0.846402 m
Critical slope
0.0107964
Efficient bottom width
0.825567 m
Efficient depth
1.74858 m
Conveyance gain
12.1861%

Interpreting this example

The comparison fixes wetted area, lining roughness and grade. Bank stability, construction width and land take may favor a different section.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.