Worked example

Wide vegetated floodway

A broad 24 m floodway with 4H:1V banks is checked for 92 m³/s using a single representative n of 0.04.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 2.91118 m, Critical depth: 1.07476 m, Froude: 0.191123, Specific energy: 2.95125 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH2.9112 mCRITICAL DEPTH1.0748 mFROUDE0.19112SPECIFIC E2.9513 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.19112

Calculation details

Section shape
Trapezoidal
Wetted area
103.768 m²
Water surface width
47.2894 m
Wetted perimeter
48.0062 m
Hydraulic radius
2.16156 m
Mean velocity
0.886592 m/s
Minimum specific energy
1.54127 m
Critical slope
0.0162315
Efficient bottom width
1.21714 m
Efficient depth
4.94346 m
Conveyance gain
9.35106%

Interpreting this example

The section efficiency comparison applies to the modeled wetted cross section. A compound floodplain requires separate roughness and overbank conveyance.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet