Worked example
Lined irrigation canal
A 3.2 m main canal has 1.5H:1V lining and a 0.09% design grade. Use the design delivery of 6.8 m³/s.
Inputs
Hydraulic readout
Subcritical flow
Normal depth: 0.993266 m, Critical depth: 0.689144 m, Froude: 0.536898, Specific energy: 1.10191 m
Input values
- Discharge Q
- 6.8 m³/s
- Bottom width b
- 3.2 m
- Side slope z (H:1V)
- 1.5
- Bed slope S₀
- 9e-4
- Manning n
- 0.016
Calculation details
- Section shape
- Trapezoidal
- Wetted area
- 4.65832 m²
- Water surface width
- 6.1798 m
- Wetted perimeter
- 6.78127 m
- Hydraulic radius
- 0.686939 m
- Mean velocity
- 1.45975 m/s
- Minimum specific energy
- 0.966096 m
- Critical slope
- 0.00338402
- Efficient bottom width
- 0.900705 m
- Efficient depth
- 1.48741 m
- Conveyance gain
- 5.43605%
Interpreting this example
The velocity and critical slope help flag a storage-sensitive reach. Apply the same roughness and wetted area when comparing conveyance.
Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)
Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.
Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.
Worked examples
Open a case to load its inputs and interpretation.
- Chow’s 400 cfs trapezoidA 20 ft bottom with 2H:1V side slopes carries 400 cfs. Use Chow’s 0.0016 grade and n = 0.025 to reproduce the published uniform-flow section.
- Concrete rectangular drainA 1.8 m concrete stormwater drain carries 4.6 m³/s with square corners and a surveyed 0.35% invert slope.
- Triangular roadside ditchA grass-lined ditch with no flat bottom has 3H:1V sides. Screen its depth at a runoff flow of 0.48 m³/s.
- Steep flume approachA 1.1 m rectangular approach chute drops on a 3.4% grade and carries 2.1 m³/s over a smooth invert.
- Wide vegetated floodwayA broad 24 m floodway with 4H:1V banks is checked for 92 m³/s using a single representative n of 0.04.
- Efficient earth-channel sectionCompare an existing 6 m bottom with the hydraulically efficient cross section at a fixed 2H:1V side slope and 9.5 m³/s.