Worked example

Lined irrigation canal

A 3.2 m main canal has 1.5H:1V lining and a 0.09% design grade. Use the design delivery of 6.8 m³/s.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 0.993266 m, Critical depth: 0.689144 m, Froude: 0.536898, Specific energy: 1.10191 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH0.99327 mCRITICAL DEPTH0.68914 mFROUDE0.5369SPECIFIC E1.1019 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.5369

Calculation details

Section shape
Trapezoidal
Wetted area
4.65832 m²
Water surface width
6.1798 m
Wetted perimeter
6.78127 m
Hydraulic radius
0.686939 m
Mean velocity
1.45975 m/s
Minimum specific energy
0.966096 m
Critical slope
0.00338402
Efficient bottom width
0.900705 m
Efficient depth
1.48741 m
Conveyance gain
5.43605%

Interpreting this example

The velocity and critical slope help flag a storage-sensitive reach. Apply the same roughness and wetted area when comparing conveyance.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.