Worked example

Steep flume approach

A 1.1 m rectangular approach chute drops on a 3.4% grade and carries 2.1 m³/s over a smooth invert.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Supercritical flow

Normal depth: 0.388679 m, Critical depth: 0.71897 m, Froude: 2.51582, Specific energy: 1.61872 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH0.38868 mCRITICAL DEPTH0.71897 mFROUDE2.5158SPECIFIC E1.6187 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 2.5158

Calculation details

Section shape
Rectangular
Wetted area
0.427547 m²
Water surface width
1.1 m
Wetted perimeter
1.87736 m
Hydraulic radius
0.227739 m
Mean velocity
4.91174 m/s
Minimum specific energy
1.07846 m
Critical slope
0.00654121
Efficient bottom width
0.924713 m
Efficient depth
0.462356 m
Conveyance gain
1.00437%

Interpreting this example

A normal depth below critical depth indicates supercritical approach. Check whether a downstream measurement station needs a tranquil approach reach.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet