Worked example

Triangular roadside ditch

A grass-lined ditch with no flat bottom has 3H:1V sides. Screen its depth at a runoff flow of 0.48 m³/s.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 0.416992 m, Critical depth: 0.349583 m, Froude: 0.643512, Specific energy: 0.460161 m

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH0.41699 mCRITICAL DEPTH0.34958 mFROUDE0.64351SPECIFIC E0.46016 mWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.64351

Calculation details

Section shape
Triangular
Wetted area
0.521646 m²
Water surface width
2.50195 m
Wetted perimeter
2.63729 m
Hydraulic radius
0.197796 m
Mean velocity
0.920165 m/s
Minimum specific energy
0.436978 m
Critical slope
0.0230492
Efficient bottom width
0.128561 m
Efficient depth
0.396115 m
Conveyance gain
0.0879346%

Interpreting this example

At b = 0 the wetted perimeter comes entirely from the banks. The efficient width compares this V section with a trapezoid of equal wetted area.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet