PowerConvLab · Design worksheet
120 V design at a measured 91 V low line
Bus design headroom available · Voltage headroom includes the entered surge allowance. Check inrush, capacitor tolerance and ripple-current rating separately.
Inputs
- Nominal AC input
- 120 V RMS
- Low-line input mode
- Enter low-line RMS voltage
- Low-line AC input
- 91 V RMS
- High-line increase
- 10 %
- Line frequency
- 60 Hz
- Rectifier topology
- Full-wave bridge
- Drop per conducting diode
- 0.95 V
- Downstream output power
- 55 W
- Downstream efficiency
- 87 %
- Bus ripple target
- 19 V
- Minimum DC bus
- 88 V
- Hold-up time unit
- Milliseconds
- Required hold-up time
- 13 ms
- Installed bulk capacitance
- 0 µF
- Capacitor voltage rating
- 250 V
- Additional surge allowance
- 0 V
Calculated results
- Low-line input
- 91 V RMS
- Low-line rectified peak
- 126.793 V
- Nominal rectified peak
- 167.806 V
- High-line rectified peak
- 184.776 V
- High-line stress with surge allowance
- 184.776 V
- Constant power from bus
- 63.2184 W
- Valley at ripple target
- 107.793 V
- Estimated operating valley
- 117.851 V
- Estimated peak-to-peak ripple
- 8.94246 V
- Discharge interval at ripple target
- 6.87359 ms
- Capacitance for ripple
- 194.984 µF
- Capacitance for hold-up
- 424.129 µF
- Governing capacitance
- 424.129 µF
- Governing requirement
- Hold-up
- Capacitance used in readout
- 424.129 µF
- Estimated hold-up from valley
- 20.6127 ms
- Hold-up headroom
- 7.61273 ms
- Bus ripple headroom
- 10.0575 V
- High-line voltage headroom
- 65.2238 V