PowerConvLab · Design worksheet
18 V AC half-wave auxiliary supply
Bus design headroom available · Voltage headroom includes the entered surge allowance. Check inrush, capacitor tolerance and ripple-current rating separately.
Inputs
- Nominal AC input
- 18 V RMS
- Low-line input mode
- Apply line tolerance
- Low-line reduction
- 10 %
- High-line increase
- 12 %
- Line frequency
- 60 Hz
- Rectifier topology
- Half-wave rectifier
- Drop per conducting diode
- 0.72 V
- Downstream output power
- 3.2 W
- Downstream efficiency
- 83 %
- Bus ripple target
- 5.5 V
- Minimum DC bus
- 12 V
- Hold-up time unit
- Milliseconds
- Required hold-up time
- 7 ms
- Installed bulk capacitance
- 680 µF
- Capacitor voltage rating
- 35 V
- Additional surge allowance
- 0 V
Calculated results
- Low-line input
- 16.2 V RMS
- Low-line rectified peak
- 22.1903 V
- Nominal rectified peak
- 24.7358 V
- High-line rectified peak
- 27.7905 V
- High-line stress with surge allowance
- 27.7905 V
- Constant power from bus
- 3.85542 W
- Valley at ripple target
- 16.6903 V
- Estimated operating valley
- 17.945 V
- Estimated peak-to-peak ripple
- 4.24527 V
- Discharge interval at ripple target
- 14.7897 ms
- Capacitance for ripple
- 533.295 µF
- Capacitance for hold-up
- 401.115 µF
- Governing capacitance
- 533.295 µF
- Governing requirement
- Ripple
- Capacitance used in readout
- 680 µF
- Estimated hold-up from valley
- 15.6994 ms
- Hold-up headroom
- 8.69938 ms
- Bus ripple headroom
- 1.25473 V
- High-line voltage headroom
- 7.20945 V