400 Hz bridge with one-cycle ride-through

Size storage for one cycle of 400 Hz AC input.

Design inputs

Mains & bridge
Bus requirements

Enter 0 to use the governing capacitance.

View live readout ↑

Live readout

Edit inputs
Bulk cap
33.52 µF
Bus valley
126.8 V
Bus ripple
9.54 V
Hold-up
3.094 ms
Bulk capacitor bus Bulk capacitor bus 400 Hz mains VbusRipple cycleMains outageLow-line pk136 VBus floor95 VHold-up3.09 ms
The outage begins at the settled low-line valley. The bus voltage drops as stored capacitor energy supplies a constant load.
Bus design headroom available

Voltage headroom includes the entered surge allowance. Check inrush, capacitor tolerance and ripple-current rating separately.

Bus stress / voltage rating177 V / 250 V

Bus ripple / goal9.54 V / 15 V

Required / available hold-up2.5 ms / 3.094 ms

Result breakdown
Low-line input97.75 V RMS
Low-line rectified peak136.339 V
Nominal rectified peak160.735 V
High-line rectified peak176.998 V
High-line stress with surge allowance176.998 V
Constant power from bus38.2022 W
Valley at ripple target121.339 V
Estimated operating valley126.8 V
Estimated peak-to-peak ripple9.53957 V
Discharge interval at ripple target1.06293 ms
Capacitance for ripple21.0113 µF
Capacitance for hold-up33.5211 µF
Governing capacitance33.5211 µF
Governing requirementHold-up
Capacitance used in readout33.5211 µF
Estimated hold-up from valley3.09446 ms
Hold-up headroom0.594458 ms
Bus ripple headroom5.46043 V
High-line voltage headroom73.002 V

Worked calculation

Cbulk = max(21.0113 µF for ripple, 33.5211 µF for hold-up) = 33.5211 µF

One mains cycle is 2.5 ms even though a full-wave bridge recharges twice per cycle.

Rectified peaks

Vpk,min = √2 · Vac,min − n · Vf | n = 2 (bridge), 1 (half wave)

Full-wave recharge events occur twice per mains cycle. Half-wave recharge occurs once. Under the ideal source model, recharge begins when the rising rectified sine crosses the falling bus.

Ripple & outage energy

Cripple = 2·Pin·tdis/(Vpk,min² − Vvalley²) | Chold = 2·Pin·thold/(Vvalley² − Vmin²)

Vvalley is the low-line peak minus target ripple. Sizing hold-up from that target valley is conservative. For the selected capacitance, the readout solves the modeled crossing and calculates available hold-up from its operating valley.

Hardware checks

Vheadroom = Vrated − (Vpk,high + Vsurge)

This margin covers the steady high-line crest plus the entered surge allowance. Verify surge waveform, ripple-current rating, tolerance and useful life against the actual capacitor. A real bridge requires inrush limiting, source-impedance and charge-pulse checks.