PowerConvLab · Design worksheet
Bulk capacitor with inadequate high-line rating
Bus design limit exceeded · Voltage headroom includes the entered surge allowance. Check inrush, capacitor tolerance and ripple-current rating separately.
Inputs
- Nominal AC input
- 230 V RMS
- Low-line input mode
- Apply line tolerance
- Low-line reduction
- 12 %
- High-line increase
- 12 %
- Line frequency
- 50 Hz
- Rectifier topology
- Full-wave bridge
- Drop per conducting diode
- 0.95 V
- Downstream output power
- 65 W
- Downstream efficiency
- 91 %
- Bus ripple target
- 20 V
- Minimum DC bus
- 175 V
- Hold-up time unit
- Milliseconds
- Required hold-up time
- 17 ms
- Installed bulk capacitance
- 220 µF
- Capacitor voltage rating
- 350 V
- Additional surge allowance
- 0 V
Calculated results
- Low-line input
- 202.4 V RMS
- Low-line rectified peak
- 284.337 V
- Nominal rectified peak
- 323.369 V
- High-line rectified peak
- 362.401 V
- High-line stress with surge allowance
- 362.401 V
- Constant power from bus
- 71.4286 W
- Valley at ripple target
- 264.337 V
- Estimated operating valley
- 273.713 V
- Estimated peak-to-peak ripple
- 10.6238 V
- Discharge interval at ripple target
- 8.80304 ms
- Capacitance for ripple
- 114.602 µF
- Capacitance for hold-up
- 61.8761 µF
- Governing capacitance
- 114.602 µF
- Governing requirement
- Ripple
- Capacitance used in readout
- 220 µF
- Estimated hold-up from valley
- 68.2125 ms
- Hold-up headroom
- 51.2125 ms
- Bus ripple headroom
- 9.37621 V
- High-line voltage headroom
- -12.4014 V