120 V design at a measured 91 V low line

Use a known low-line RMS value to assess a 60 Hz bridge; nominal and high line remain specified separately.

Design inputs

Mains & bridge
Bus requirements

Enter 0 to use the governing capacitance.

View live readout ↑

Live readout

Edit inputs
Bulk cap
424.1 µF
Bus valley
117.9 V
Bus ripple
8.942 V
Hold-up
20.61 ms
Bulk capacitor bus Bulk capacitor bus 60 Hz mains VbusRipple cycleMains outageLow-line pk127 VBus floor88 VHold-up20.6 ms
The outage begins at the settled low-line valley. The bus voltage drops as stored capacitor energy supplies a constant load.
Bus design headroom available

Voltage headroom includes the entered surge allowance. Check inrush, capacitor tolerance and ripple-current rating separately.

Bus stress / voltage rating184.8 V / 250 V

Bus ripple / goal8.942 V / 19 V

Required / available hold-up13 ms / 20.61 ms

Result breakdown
Low-line input91 V RMS
Low-line rectified peak126.793 V
Nominal rectified peak167.806 V
High-line rectified peak184.776 V
High-line stress with surge allowance184.776 V
Constant power from bus63.2184 W
Valley at ripple target107.793 V
Estimated operating valley117.851 V
Estimated peak-to-peak ripple8.94246 V
Discharge interval at ripple target6.87359 ms
Capacitance for ripple194.984 µF
Capacitance for hold-up424.129 µF
Governing capacitance424.129 µF
Governing requirementHold-up
Capacitance used in readout424.129 µF
Estimated hold-up from valley20.6127 ms
Hold-up headroom7.61273 ms
Bus ripple headroom10.0575 V
High-line voltage headroom65.2238 V

Worked calculation

Cbulk = max(194.984 µF for ripple, 424.129 µF for hold-up) = 424.129 µF

Compare the nominal peak and low-line peak. The lower peak sets the stored energy available to the load.

Rectified peaks

Vpk,min = √2 · Vac,min − n · Vf | n = 2 (bridge), 1 (half wave)

Full-wave recharge events occur twice per mains cycle. Half-wave recharge occurs once. Under the ideal source model, recharge begins when the rising rectified sine crosses the falling bus.

Ripple & outage energy

Cripple = 2·Pin·tdis/(Vpk,min² − Vvalley²) | Chold = 2·Pin·thold/(Vvalley² − Vmin²)

Vvalley is the low-line peak minus target ripple. Sizing hold-up from that target valley is conservative. For the selected capacitance, the readout solves the modeled crossing and calculates available hold-up from its operating valley.

Hardware checks

Vheadroom = Vrated − (Vpk,high + Vsurge)

This margin covers the steady high-line crest plus the entered surge allowance. Verify surge waveform, ripple-current rating, tolerance and useful life against the actual capacitor. A real bridge requires inrush limiting, source-impedance and charge-pulse checks.