PowerConvLab · Design worksheet
PC40 ferrite close to its hot flux limit
Low flux headroom · Saturation uses the selected threshold. Check flux and inductance at operating temperature.
Inputs
- Winding turns
- 14 turns
- Target inductance
- 22 µH
- Effective core area
- 70 mm²
- Magnetic path length
- 52 mm
- Effective core volume
- 3.64 cm³
- Peak current magnitude
- 15.6 A
- AC peak-to-peak current
- 3.2 A
- Switching frequency
- 135 kHz
- Core material
- PC40 ferrite · 380 mT
Calculated results
- Peak flux density
- 350.204 mT
- Minimum flux density
- 278.367 mT
- AC flux swing (peak-to-peak)
- 71.8367 mT
- AC flux amplitude
- 35.9184 mT
- Midpoint DC current
- 14 A
- DC magnetizing field
- 3,769.23 A/m
- Material saturation threshold
- 380 mT
- Peak-flux headroom
- 29.7959 mT
- Peak-flux headroom
- 7.84103 %
- Relative permeability used
- 2,300
- Equivalent discrete air gap
- 0.761076 mm
- Estimated ungapped inductance
- 762.585 µH
- Steinmetz coefficient k
- 4.11814
- Steinmetz frequency exponent α
- 1.29248
- Steinmetz flux exponent β
- 2.08
- Modeled magnetic loss density
- 17,402.8 W/m³
- Modeled core loss
- 0.0633462 W