PowerConvLab · Design worksheet
Sendust choke with a distributed gap
Flux headroom available · The gap is an equivalent reluctance. Use the powder core DC-bias curve for actual inductance.
Inputs
- Winding turns
- 28 turns
- Target inductance
- 33 µH
- Effective core area
- 85 mm²
- Magnetic path length
- 61 mm
- Effective core volume
- 5.19 cm³
- Peak current magnitude
- 10 A
- AC peak-to-peak current
- 3 A
- Switching frequency
- 125 kHz
- Core material
- Sendust / Kool Mµ · 1,000 mT
Calculated results
- Peak flux density
- 138.655 mT
- Minimum flux density
- 97.0588 mT
- AC flux swing (peak-to-peak)
- 41.5966 mT
- AC flux amplitude
- 20.7983 mT
- Midpoint DC current
- 8.5 A
- DC magnetizing field
- 3,901.64 A/m
- Material saturation threshold
- 1,000 mT
- Peak-flux headroom
- 861.345 mT
- Peak-flux headroom
- 86.1345 %
- Relative permeability used
- 60
- Equivalent discrete air gap
- 1.52098 mm
- Estimated ungapped inductance
- 82.3695 µH
- Steinmetz coefficient k
- 1.05537
- Steinmetz frequency exponent α
- 1.541
- Steinmetz flux exponent β
- 1.988
- Modeled magnetic loss density
- 34,196.5 W/m³
- Modeled core loss
- 0.17748 W