Sendust choke with a distributed gap

Apply a representative 60-permeability sendust grade to a 33 µH choke.

Design inputs

Winding & geometry
Excitation & material
View live readout ↑

Live readout

Edit inputs
Peak flux
138.7 mT
Flux headroom
86.13 %
Air gap
1.521 mm
Core loss
0.1775 W
Core magnetization Core magnetization B–H reference BField H → Equivalent gapPeak B139 mTSaturation1000 mTAir gap1.52 mm
The B–H curve and gap are illustrative. The marker and labels follow the calculated flux and the selected material threshold.
Flux headroom available

The gap is an equivalent reluctance. Use the powder core DC-bias curve for actual inductance.

Peak flux / saturation138.7 mT / 1,000 mT

AC flux amplitude / saturation20.8 mT / 1,000 mT

Result breakdown
Peak flux density138.655 mT
Minimum flux density97.0588 mT
AC flux swing (peak-to-peak)41.5966 mT
AC flux amplitude20.7983 mT
Midpoint DC current8.5 A
DC magnetizing field3,901.64 A/m
Material saturation threshold1,000 mT
Peak-flux headroom861.345 mT
Peak-flux headroom86.1345 %
Relative permeability used60
Equivalent discrete air gap1.52098 mm
Estimated ungapped inductance82.3695 µH
Steinmetz coefficient k1.05537
Steinmetz frequency exponent α1.541
Steinmetz flux exponent β1.988
Modeled magnetic loss density34,196.5 W/m³
Modeled core loss0.17748 W

Worked calculation

Bmax = 33 µH × 10 A / (28 × 85 mm²) = 138.655 mT

Read the equivalent gap as a reluctance check. Compare the selected grade’s DC-bias curve before choosing a physical core.

Flux

Bmax = L·Ipk/(N·Ae) | ΔB = L·ΔIpp/(N·Ae)

Compare the absolute endpoint flux with the saturation threshold. A bipolar peak-to-peak swing can exceed that threshold while both endpoints stay within it. Hdc = N·Idc/ℓe uses the midpoint of the entered triangular current. Use it with the actual powder-core DC-bias curve and enter inductance at the operating bias.

Gap

ℓg = μ₀·N²·Ae/L − ℓe/μr

If the computed gap is negative, the ungapped core cannot reach the target L at this turn count. The estimate neglects fringing and uses linear permeability. For a powder core the result is an equivalent reluctance, not a machining dimension.

Core loss

Pcore = Ve · k · fs^α · (ΔB/2)^β

Enter frequency in Hz and flux in tesla when fitting custom coefficients for a loss density in W/m³. Ferrite coefficients are approximate fits to typical hot datasheet points. Powder presets use published coefficients for representative 60-permeability toroids. Use your exact material, geometry, temperature and waveform for final loss estimates.