12 V universal-input flyback

Plan a 24 W isolated supply with a DC bus spanning rectified low and high line.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
6 : 1
Primary Lₘ
957.3 µH
Drain Vₚₖ
532.9 V
Clamp loss
0.3152 W
Flyback drain voltage Flyback drain voltage High line · 10 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak533 VPlateau450 VClamp loss0.315 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain headroom available

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating532.9 V / 650 V

Reflected voltage / duty limit75 V / 84.92 V

Result breakdown
Primary : secondary turns6 : 1
Primary magnetizing inductance957.294 µH
Low-line duty44.9102 %
Maximum reflected voltage at duty limit84.9231 V
Primary peak across line range0.899179 A
Worst primary RMS0.465514 A
Primary RMS at low line0.465514 A
Primary RMS at high line0.199839 A
Secondary peak across line range5.39507 A
Worst secondary RMS3.09348 A
Secondary RMS at low line3.09348 A
Secondary RMS at high line2.68112 A
High-line conduction modeCCM
Estimated high-line drain peak532.85 V
Drain voltage headroom117.15 V
RCD clamp dissipation0.315222 W
Clamp resistance75,236 Ω
Clamp capacitance2.6583 nF
Clamp ripple budget7.7 V
Estimated total converter loss budget4.23529 W

Worked calculation

Np/Ns = 75 V / (12 V + 0.5 V) = 6 : 1

Compare the low-line duty with the maximum. Check the primary RMS for copper loss and drain peak for voltage headroom.

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.