PowerConvLab · Design worksheet
24 V flyback with a tight drain rating
Drain rating exceeded · Drain stress includes the clamp setting at high line. Check overshoot on the bench.
Inputs
- Minimum DC input
- 100 V
- Maximum DC input
- 380 V
- Output voltage
- 24 V
- Output diode drop
- 0.6 V
- Output power
- 60 W
- Assumed efficiency
- 87 %
- Switching frequency
- 100 kHz
- Maximum duty
- 48 %
- Reflected voltage Vₒᵣ
- 85 V
- Ripple / peak Kᵣₚ
- 55 %
- Primary leakage
- 2.8 µH
- Mean clamp voltage above bus
- 148 V
- Clamp ripple (peak-to-peak)
- 5 %
- MOSFET drain rating
- 500 V
Calculated results
- Primary : secondary turns
- 3.45528 : 1
- Primary magnetizing inductance
- 403.495 µH
- Low-line duty
- 45.9459 %
- Maximum reflected voltage at duty limit
- 92.3077 V
- Primary peak across line range
- 2.07036 A
- Worst primary RMS
- 1.04155 A
- Primary RMS at low line
- 1.04155 A
- Primary RMS at high line
- 0.474695 A
- Secondary peak across line range
- 7.1537 A
- Worst secondary RMS
- 3.90351 A
- Secondary RMS at low line
- 3.90351 A
- Secondary RMS at high line
- 3.46801 A
- High-line conduction mode
- CCM
- Estimated high-line drain peak
- 531.7 V
- Drain voltage headroom
- -31.7 V
- RCD clamp dissipation
- 1.40975 W
- Clamp resistance
- 15,537.5 Ω
- Clamp capacitance
- 12.8721 nF
- Clamp ripple budget
- 7.4 V
- Estimated total converter loss budget
- 8.96552 W